Led Indicators - AEG AS-IC01 Installation Instructions Manual

Three-phase grid-tied solar inverter 4 kw to 10 kw
Table of Contents

Advertisement

31

5.1 LED indicators

There are three LED indicators on the panel:
1.
"Run", operation indicator, green;
2.
"Warn" recoverable fault indicator, yellow;
3.
"Fault", unrecoverable fault indicator, red.
The inverter state includes 6 states of stand-by, self-inspection, power generation, recoverable fault and unrecoverable
fault; LED indicators are on, off and blinking. Please refer to table 5-1 for detailed state of inverter and LED indicators
state.
" ": LED indicator is off;
" " (green), " " (yellow), " " (red): LED indicator is blinking at every 0.25S or 0.5S;
" (Green), " " (yellow), " " (red): LED indicator is on.
Inverter state
Stand-by
Self-inspection
Power generation
Recoverable fault
Unrecoverable fault
PD201809 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (4-10 kW) V.2-18 EN
LED indicators
Run
All indicators are off:
Warn
No power on
Fault
Run
Green indicator blinks in every 0.25s, others off:
Warn
Power on and ready for self-inspection
Fault
Run
Green indicator is on, others off.
Warn
The inverter is running and grid-tied power is generated)
Fault
Green and yellow indicators are on, others are off:
(1) Grid-tied power generation, but clock fault (A007);
Run
Warn
(2) Grid-tied power generation, but DC input fault (A001 or
Fault
E001);
(3) Grid-tied power generation, but fan fault (E006 or E012);
Yellow indicator blinks every 0.5s, others are off:
Run
Warn
Inverter stand-by.
Fault
Public grid fault (A001, A003, A004, A005or A006);
Yellow indicator is on, others are off:
Run
Warn
(1) Inverter stand-by. Temperature abnormal(E006);
Fault
(2) Inverter stand-by. DC input fault (E001);
Run
Warn
Red indicator blinks every 0.5s, others are off:
Fault
Description
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-ic01-2

Table of Contents