Installation

7.7.3 Making the PTP 300/500/600 Series Bridge PIDU Plus Connection At The ODU

The following procedure describes how connection is made at the ODU. It is often easier to carry
out this procedure on the ground or a suitable surface prior to mounting the ODU.
Ensure that no power is connected to the PIDU Plus or present on the cable before connecting the
ODU.
Step 1: Assemble the cable
Step 2: Insert the RJ45 connector making
as described in 5.7.1 above
sure that the locking tab snaps home
Step 3: Screw in the body of the
Step 4: Screw on the clamping nut and tighten
weather proofing gland and tighten
(Do not over tighten – see
Figure
20)
Figure 19 Connecting the PIDU+ to the ODU
CAUTION: Do not over tighten the glands as the internal seal and structure may be damaged.
See
Figure 20
for an example of an over tightened cable gland.