3.
Bosch Solar Module Electrical Characteristics
Model
c-Si M 60-225-16
c-Si M 60-230-16
c-Si M 60-235-16
c-Si M 60-240-16
Module bypass diode type, voltage rating, current rating, and configuration of the diode
Module series
c-Si M 60-225-16
c-Si M 60-230-16
c-Si M 60-235-16
c-Si M 60-240-16
NOTE:
DO NOT attempt to open the diode housing or junction box located on the back side of any Bosch Solar
module. There are no user serviceable parts inside.
4.

SAFETY INSTRUCTIONS

Handling Safety
DO NOT drop, allow objects to fall on,
or stand or step on modules.
DO NOT install during high winds.
Never leave a module unsupported or
unsecured. If a module falls, the glass
could break. A module with broken
glass cannot be repaired and must not
be used.
DO NOT disassemble the module, or
remove any part installed by Bosch So-
lar. Use modules for their intended use
Open
Rated
Circuit
Voltage at
Voltage
STC,
at STC,
(V dc)
(V dc)
36.0
28.3
36.35
28.75
36.5
29.35
36.7
29.65
Total #
Diodes # in par-
of Dio-
allel for each
des
string
3
1
3
1
3
1
3
1
Maxi-
Short
mum
Rated
Circuit
Sys-
Current at
Current at
tem
STC,
STC,
Volta-
(A dc)
(A dc)
ge, (V
dc)
600
7.95
8.7
8.0
8.75
600
600
8.0
8.75
8.1
8.8
600
Diode Manufac-
Diode
turer
Tyco
SL1010
Tyco
SL1010
Tyco
SL1010
Tyco
SL1010
only and follow all manufacturers' in-
structions.
DO NOT attempt to remove snow or ice
from the module.
DO NOT direct artificially concentrated
sunlight on the module.
Installation Safety
DO NOT attempt to install or service
any portion of the PV system unless you
understand the electrical operation and
are fully qualified to do so.
Rated
Maximum
Power
at
STC,
(Watts)
225
230
235
240
Diode Ratings
Type
(A)
11
11
11
11
Maximum
Series
Fuse,
(A)
15
15
15
15
(PIV)
40
40
40
40
3/9