6 Maintenance

6.1 Annual maintenance

1. Ensure compressed air supply unit mountings are secure.
2. Ensure push-fit couplings and 6 mm tubing are in
serviceable condition – see Section 4.1, page 9.
3. Ensure the air intake is clean – see Section 2, page 5,
O
item
.
4. Ensure the air muffler / filter is clean and free of clogged
pores – see Section 2, page 5, item
remove from the compressor head and blow oil-free
compressed air through it from the reverse side.
If the unit operates in a dusty environment, additional
periodic cleaning may be required – use only a clean, dry
cloth.
C
. To clean this,
Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B