Error message
SATA drives were detected, but this
controller does not support SATA drives.
Remove the SATA drives, and restart your
system. Press any key to continue or press C
to load the configuration utility.
Raid Key Missing.
Please check the Raid Key connection.
If problems persist contact Tech Support.
Raid Key Authentication Error.
Please check the RAID Key installed for this
solution.
If problems persist, contact Tech Support.
Raid Key OEM Authentication Error.
Install the correct RAID key for this System.
If problems persist contact Tech Support.
There are more enclosures connected to the
port than what is allowed for a single SAS
port.
Remove the extra enclosures, and then
restart your system.
Invalid SAS topology detected.
Check your cable configurations, repair the
problem, and restart your system.
Invalid AS Address present in SBR. Contact
your system support.
Press any key to continue with the default
SAS address.
Invalid SAS Address present in MFC data.
Program the valid SAS Address, and restart
your system.
Invalid memory configuration detected.
Contact your system support.
System has halted.
Entering the configuration utility in this state
will result in drive configuration changes.
Press Y to continue loading the configuration
utility or power off your system and check
your cables to ensure that all the disks are
present, and then restart.
External Enclosure does not support in
controller's Direct mapping mode.
Contact your system support.
System has halted due to unsupported
configuration.
Expander Detected in controller with Direct
mapping mode.
Reconfiguring automatically to persistent
mapping mode.
Automatic reboot would happen in 10
seconds.
Hitachi Compute Rack 210H User's Guide
The disk array controller is working with
illegal parameters.
The disk array controller is working with
illegal parameters.
The disk array controller is working with
illegal parameters.
The disk array controller is working with
illegal parameters.
An illegal enclosure has been detected.
An invalid SAS topology has been
detected.
An invalid SAS address exists.
An invalid SAS address exists.
Invalid memory configuration
information has been detected.
The HDD configuration information has
been changed.
Illegal information has been detected
from the enclosure.
An unsupported device (expander) has
been detected.
Troubleshooting
Description
Action
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
(*1)
6-11

Hide quick links: