Update of OPC UA Server
7.1
Overview
Compatibility
This version of OPC UA server is supported by SINUMERIK 840D sl and SINUMERIK 828D.
An update process is possible with SINUMERIK software version ≥ V4.7.
SINUMERIK Integrate Create MyConfig (CMC)
The necessary update (CMC) file can be provided by your regional SIEMENS office.
7.2
Installation of OPC UA server
OPC UA - Server update
The installation procedure of the OPC UA server will vary depending whether a PCU or a PPU/
NCU is being used. Below are the instructions for both options:
PCU/IPC
1. Load OPC UA software on USB stick.
2. Start PCU in the service mode.
3. Insert USB stick in USB port of operator panel.
4. Start Windows Explorer.
5. Navigate to .exe file and execute it.
6. Follow the installation instructions.
7. After successful installation, restart the PCU.
Note
If OPC UA was active before the installation, users and rights will be preserved.
PPU/NCU
1. Load OPC UA software on a bootable USB stick.
2. Insert USB stick in USB port of NCU/PPU.
3. Switch off NCU/PPU and switch it on again.
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0