Touch screen keypad

Advertisement

Quick Links

1 | Overview
This keypad is SDI2 compatible with four inputs and one output.
1
2
3
Callout ― Description
1 ― Power indicator LED
2 ― Integrated proximity reader (for use with RF ID tokens and
access cards)
3 ― Presence sensor
2 | Installation
2.1 | Remove the mounting plate
1.
Insert a slotted screwdriver under the retention clip to release
the clip. Do not twist upwards.
2.
Move the plate towards the bottom of the keypad. Refer to the
following illustration.
2.2 | Install the mounting plate
1.
Use the flush mounting plate (Left side in the following
illuistration) or the surface mounting plate (Right side in the
following illustration).
2.
Use the plate as a template to mark the wall for installation.
3.
Make sure it is level.
4.
Pull the wiring through the wiring openning.
3 | Connecting the wires to the keypad
Attach the wires to the keypad and to any inputs or outputs before you
install the keypad.
CAUTION!
Remove all power (AC and battery) before making any
connections. Failure to do so might result in personal injury
and/or equipment damage.
NOTICE!
To prevent damage to the terminals, use a ballpoint pen. Do
not use a screwdriver.
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
NOTICE!
Use the strip gauge on the plate to reduce wires to 7 mm.
Attach one wire per terminal.
1.
Put the keypad on a smooth surface.
2.
Use a ballpoint pen to press the button on the terminal release.
3.
Put the wire into the terminal. When you remove the pen, the
terminal release locks the wire.
4.
To remove wires, press the terminal release.
5.
Gently pull the wire out.
3.1 | Attach to the control panel
Use the control panel terminals labeled R, Y, G, B (PWR, A, B, COM).
Connect them to the keypad terminals labeled R, Y, G, B.
You can connect keypads to the SDI2 data bus by parallel wire run from
the control panel to each keypad, wire from keypad to keypad, or a
combination of the two techniques. Refer to the following illustrations
in this section.
R Y G B
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 13 VDC
1 k
End of Line Resistors
1
AUX
1 COM 2
3 COM 4
5 COM 6
- 12 V +
3
COM AUX
R
Y
G
B
1
COM
2
3
COM
PWR A
B COM
R Y G B
R
Y
G
B
2
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
Callout ― Description
1 ― Control panel
2 ― Terminal wiring
3 ― Keypad's wiring terminal block
R Y G B
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 13 VDC
1 k
End of Line Resistors
AUX
1 COM 2
3 COM 4
5 COM 6
- 12 V +
COM AUX
R
Y
G
B
1
COM
2
3
COM
PWR A
B COM
R Y G B
R
Y
G
B
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
PWR A
B COM
R
Y
G
B
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
PWR A
B COM
R
Y
G
B
3.2 | Attach the inputs
Wire resistance on each sensor input must be less than
100 Ω with the detection devices connected. The terminal block
supports 18 to 22 AWG (1.02 to 0.65 mm) wires.
The keypad identifies open, short, normal, and ground fault circuit
conditions on its sensor loops and transmits the conditions to the
control panel. Each sensor loop has a point number and transmits to
the control panel individually. Run wires away from any telephone
and AC wiring.
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
Callout ― Description
1 ― Keypad terminal strip
2 ― Keypad sensor loops
3 ― 1 kΩ EOL resistor (ICP-1K22AWG-10)
3.3 | Attach the output
The keypad provides one NO (normally open) output. It includes NO
and C (COMMON) terminals. When the output is active (energized),
the NO has continuity with the C terminal.
NOTICE!
Do not exceed relay contact ratings of 1.0 A, 24 VDC,
resistive load.
3.4 | Install the keypad
1.
Align the mounting hook opennings over the hooks.
2.
Push the keypad down.
4 | Set the address
Each SDI2 keypad must have a unique address. For single-digit
addresses 1 through 9, set the tens switch to 0. The following
illustration shows the address switch setting for address 1.
NOTICE!
Only use your finger or a touch screen stylus on the
keypad.
1.
To show the start up screen, apply power to the keypad or push
Time/Date for 5 seconds. You can also push anywhere on Call for
Service screen.
2.
Hold the countdown icon for 5 seconds to show the addressing page.
3.
Use the up and down arrows to change the ones and tens digits.
4.
Push
(Escape) to save the setting and return to the power up
screen.
5 | Status indicators
Status
Function
indicator
Ready to turn on (arm)
Turned on (armed)
System trouble
GAS
Gas alarm
AC power present

Advertisement

loading