Final check (installer to check before leaving)
1. Open gas supply.
2. Check gas installations for secure fitting and
tightness.
3. Ignite burners and check appearance of the flarne.
4. Gas leakage, setting the test point, setting tt1e
turndown, ensuring complete ignition of all burners.
5. For ott1er minor adjustments or if the appliance
does not perform correctly contact: Beko A and NZ Pty
Ltd 1300 282 356
m
Fiame must be blue and have a regular shape.
If the flame is yellowish, check if the burner
cap is seated securely or clean the burner.
Gas conversion
m~~~r~~~rting
any work on the gas
·
installation, disconnect the gas supply.
There is the risk of explosion!
In order to change your appliance's gas type, change
all injectors and make flame adjustment for all valves
at reduced flow rate position.
Exchange of injector for the burners
1. Take off burner cap and burner body.
2. Unscrew injectors by turning the counter-
clockwise.
3. Fit new injectors.
4. Check all connections for secure fitting and
ti htness.
New injectors have their position marked on
heir packing or injector table on
Injector table,
~~~~~~oo-•.Page
10
can be referred to.
((Varies depending on the product model.))
On some hob burners, the injector is covered
lllllloo-""'•with a metal piece. This metal cover must be
2
1
2
3
4
removed for injector replacement.
I
I
I
I
I
Flame failure device (model dependant)
Spark plug
Injector
Burner
Unless there is an abnormal condition, do not
attempt to remove the gas burner taps. You
must call an Authorised service agent or
technician with licence if it is necessary to
change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted and turn
the knob to the reduced position.
2. Rernove the knob frorn the gas tap.
3. Use an appropriately sized screwdriver to adjust
the flow rate adjustment screw.
For LPG (Butane - Propane) turn the screw clockwise.
For the natural gas, you should turn the screw
counter -clockwiseonce.
»The norrnallength of a straight flarne in the reduced
position should be 6-7 rnrn.
4. If the flarne is higher than the desired position,
turn the screw clockwise. If it is srnaller turn
anticlockwise.
5. For the last control, bring the burner both to high-
flame and reduced positions and check whether
the flarne is on or off.
Depending on the type of gas tap used in your
appliance the adjustment screw position rnay vary.
15/EN