6.4 Connection Diagrams

6.4.1 Precautions when connecting GT

-If noise is a problem, use a shielded cable and employ countermeasures such as installing a ferrite core
if necessary. Also take measures so that the shielding doesn't peel off and noise such as static electricity
does not interfere.
-The number of units, transmission distance and baud rate may differ depending on the device
connected. Verify with the device being used.
-The maximum cable length for RS232C type is 15 m, also RS422 (5 V) type is 30 m.
-The maximum transmission distance is 500 m for the 24 V RS422 type.
-When connecting to the RS485, it may not be connected depending on the timing for switching between
the transmission and reception at the external device. Please check it using the actual equipment.
The terminal unit setting varies according to the external device to be connected. Confirm it before
setting a terminal unit.

6.4.2 RS232C Connection

- GT01
- When not performing CS/RS control (except GT01)
Note) The CS/RS at the GT side should be short-circuited.
However, short-circuiting is not required when setting "CS/RS Control" to "Off" in the "Communication
Parameter" tab in the GTWIN "GT Configuration" dialog box.
- When performing CS/RS control (except GT01)