9.Parameter data

Explanation of parameters for VF-S15 series is described here. For communication purposes, see
the parameter list on inverter's instruction manual regarding the communication number, adjustment
range and so forth.
 Referring to the parameter list
<Example of excerpts from the inverter's instruction manual>
Commu-
Title
nication
No.
-
History function
auh
Apprication easy
aua
setting
-
Guidance function
auf
0094
Overload character-
aul
istic selection
0000
Automatic accelera-
au1
tion/deceration
acc
0009
Acceleration time 1
- The summary of parameter list relating to the communication is as follows.
(1) "Title" means the display on the inverter panel.
(2)
"Communication number" is affixed to each parameter that is necessary for designating the parameter for com-
munication.
(3) "Adjustment range" means a data range adjustable for a parameter, and the data cannot be written outside the
range. The data have been expressed in the decimal notation. For writing the data through the communication
function, take the minimum setting unit into consideration, and use hexadecimal system.
(4) "Minimum setup unit" is the unit of a single data (when the minimum setting unit is "-", 1 is equal to 1).
For example, the "minimum setting unit" of acceleration time ( acc ) is 0.1, and 1 is equal to 0.1s. For setting a
data to 10 seconds, transmit 64h [10 ÷ 0.1=100d=64h] by communication.
If 0999 is equal to 2, the acceleration/deceleration time parameters acc , dec , f500 , f501 , f510 ,
f511 can be set in units of 0.1 sec. If 0999 is equal to 1, these parameters can be set in units of 0.01 sec.
 Acceleration/deceleration setting time unit (0999)
Communication No.
0999
Note: Don't write the communication number of 0999. The acceleration/deceleration time unit is set by f519 .
(5) When data is a negative number, it treats as an one's complement expression (ex. FFFFH is equal to '-1').
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Function
Adjustment range
-
-
-
0:-
1:Constant torque charac-
teristic (150%-60s)
2:Variable torque charac-
teristic (120%-60s)
0:Disabled(manual setting)
1:Automatic
2:Automatic(only at accel-
eration)
0.0~3600 sec.
:
Function name
Acceleration/deceleration time unit
Minimum
setting unit
(Panel/Communi
cation)
-
-
-
1/1
1/1
0.1/0.1
Unit
1: 0.01 sec. (0.01-360.00)
-
2: 0.1 sec. (0.1-3600.0)
67
E6581913
Default
Ref-
setting
erenc
e
-
4.3
5.1
0
0
4.3
5.2
0
3.5
5.3
6.14
0
5.4
10.0
5.4
Adjustment range