Chapter 6
RUGGEDCOM ROX II Actions
<time>
<ntp>
<ntp-status/>
</ntp>
</time>
</services>
</data>
</action>
</rpc>]]>]]>
Section 6.3.2

log (Link-Failover)

This action displays the link failover log. This action does not take any parameters.
<rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<action xmlns="http://tail-f.com/ns/netconf/actions/1.0">
<data>
<services xmlns="http://ruggedcom.com/ns/rmf_services">
<link-failover>
<main>{ip-interface-name}</main>
<log/>
</link-failover>
</services>
</data>
</action>
</rpc>]]>]]>
Section 6.3.3

start-test (Link Failover)

This action starts a test of the link failover function. Specify the name of the interface to test in the <name>
element. Parameters include <test-duration> and <start-test-delay>.
<rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<action xmlns="http://tail-f.com/ns/netconf/actions/1.0">
<data>
<services xmlns="http://ruggedcom.com/ns/rmf_services">
<link-failover>
<main>{interfaceName}</main>
<start-test>
<test-duration>{testDuration}</test-duration>
<start-test-delay>{testDelay}</start-test-delay>
</start-test>
</link-failover>
</services>
</data>
</action>
</rpc>]]>]]>
• {interfaceName}
The name of the interface on which to perform the link failover test.
• {testDuration}
The amount of time, in minutes, to run the test before restoring service to the main trunk.