Siemens SIMATIC S7-400 Operating Instructions Manual page 110

Industrial ethernet
Hide thumbs Also See for SIMATIC S7-400:
Table of Contents

Advertisement

Programming the OPC UA client blocks
5.10 Error numbers
Done Error
ErrorID (hex) Name
0
1
00A30000
0
1
00A50000
0
1
00A60000
0
1
00A70000
0
1
00A80000
0
1
00A90000
0
1
00AA0000
0
1
00BA0000
0
1
406C0000
0
1
408F0000
0
1
40900000
0
1
40910000
0
1
40920000
0
1
40930000
0
1
40940000
0
1
40950000
0
1
40A40000
0
1
40BC0000
0
1
40C00000
0
1
80010000
0
1
80020000
0
1
80030000
0
1
80040000
0
1
80050000
0
1
80060000
0
1
80070000
0
1
80080000
0
1
80B80000
0
1
80B90000
0
1
80B90000
110
GoodEntryReplaced
GoodNoData
GoodMoreData
GoodCommunicationEvent
GoodShutdownEvent
GoodCallAgain
GoodNonCriticalTimeout
GoodResultsMayBe
Incomplete
UncertainReferenceOutOf
Server
UncertainNoCommunication
LastUsableValue
UncertainLastUsableValue
UncertainSubstituteValue
UncertainInitialValue
UncertainSensorNotAccurate The value is at one of the sensor limits.
UncertainEngineeringUnits
Exceeded
UncertainSubNormal
UncertainDataSubNormal
UncertainReferenceNot
Deleted
UncertainNotAllNodes
Available
BadUnexpectedError
BadInternalError
BadOutOfMemory
BadResourceUnavailable
BadCommunicationError
BadEncodingError
BadDecodingError
BadEncodingLimits-
Exceeded
BadRequestTooLarge
BadResponseTooLarge
BadUnknownResponse
Meaning
The data or event field was successfully replaced in the his-
torical database.
No data exists for the requested time range or event filter.
The data or event field was successfully replaced in the his-
torical database.
The communication layer has raised an event.
The system is shutting down.
The operation is not finished and needs to be called again.
A non-critical timeout occurred.
The server should have followed a reference to a node in a
remote server but did not. The result set may be incomplete.
One of the references to follow in the relative path references
to a node in the address space in another server.
Communication to the data source has failed. The variable
value is the last value that had a good quality.
Whatever was updating this value has stopped doing so.
The value is an operational value that was manually overwrit-
ten.
The value is an initial value for a variable that normally re-
ceives its value from another variable.
The value is outside of the range of values defined for this
parameter.
The value is derived from multiple sources and has less than
the required number of Good sources.
The value is derived from multiple values and has less than
the required number of Good values.
The server was not able to delete all target references.
The list of references may not be complete because the un-
derlying system is not available.
An unexpected error occurred
An internal error occurred as a result of a programming or
configuration error.
Not enough memory to complete the operation.
An operating system resource is not available
A low level communication error occurred.
Encoding halted because of invalid data in the objects being
serialized.
Decoding halted because of invalid data in the stream.
The message encoding/decoding limits imposed by the stack
have been exceeded.
The resources (memory) of the CPU are temporarily occu-
pied
The response message size exceeds limits set by the client.
An unrecognized response was received from the server.
Operating Instructions, 01/2017, C79000-G8976-C427-02
CP 443-1 OPC UA