Pioneer CYB Series Installation Manual page 10

Ductless mini split system air conditioner/heat pump (cooling-only version, cooling and heating version) 9,000-18,000 btu/hr
Hide thumbs Also See for CYB Series:
Table of Contents

Advertisement

2.3 Installation
uidelines
G
When a wall, or other obstacle, is in the path of outdoor unit's
inlet or outlet airflow, follow the installation guidelines below.
For any of the below installation patterns, the wall height on the
outlet side should be 1200mm/47.2in, or less.
I Against a straight wall
More than 100
Side view
I
I
Against corner wall
Top view
I
I
A gainst 3-sided wall
g
More than 50
Top view
More than 350
More than 50
一 .
0
M
h
1
0
re
a
n
7
0
O
M
h
3
5
re
a
n
O
t
Unit:mm
(in=mm/25.4)
2.4 Outdoor
nit Installation
U
1) Installing Outdoor
When installing the outdoor unit, refer to "Precautions for
"
Location Selection
Check the sturdiness of the installation ground so that
the unit will not cause any operating vibration or noise once
installation is complete.
Fix the unit securely by means of foundation bolts.
(Prepare 4 sets of M8 or M10 foundation bolts, nuts, and
washers, each which are available on the ma
2)
Drain
ork
W
If drain work is necessary, follow the procedu「es below.
Use a drain plug for drainage.
If the drain port is covered by a mounting base or floor surface,
place additional foot bases, of at least 30mm/1.2 in in height,
underneath the outdoor unit's feet.
In cold areas, do not use a drain hose with the outdoor unit.
(Otherwise, the drain water may freeze, impairing heating
performance.)
B ottom !c ame
8
nit:
U
ket.)
D
ain port
勹二 ::: : ' ' " '