3-8
Guide Indication
The indication of the center position and actual marking character string can be traced (guide indication) on
the actual work using the red laser.
The operation of the guide indication is performed in PC control mode.
•
When activating the guide indication, perform the guide indication with the shutter (guide
indication switching lever) closed.
•
Since the power of the guide laser is 1mW or less (red), work is not processed in almost all
cases. However, the color change may be caused on an object sensitive to red. Do not use the
laser for guide indication for such object.
CHECK
•
When performing the guide indication, the file under editing is transferred to the head, and
overwritten to the file with the same file No. in the head. Therefore, pay attention to the
activation of the guide indication.
3-8-1 Center Position Indication
When the shutter (guide indication switching lever) is set to "CLOSE", the marking center position is indicated
with the red laser.
The guide laser is irradiated to the center of the marking area without using the guide indicating
function by setting the shutter lever to "CLOSE".
CHECK
3-8-2 Guide Indication
1 "File" - "GUIDE"
2 Click
Select operation from either "1" or "2" described above.
When the shutter is set to "OPEN", the dialog box that indicates the shutter is in open state is appeared.
Click "OK", set the shutter to "CLOSE", and select the operation from either "1" or "2" described above.
When the shutter is set to "CLOSE", the dialog box indicating "Start of guide indication" is appeared.
134
.
(1)
(2)
(3)