1.2: Length Unit (F = m)
Units of measurement
Value
1.3: Nozzle Height (F = 0 m)
Length of nozzle from top of flange to top of vessel (see Functional Dimensions on page
33)
Value
1.4: Tank Height (F = 20 m)
Height of vessel from bottom of nozzle to bottom of vessel (see Functional Dimensions on
page 33)
Value
1.5: Level URV (F = 20 m)
Full scale of level (see Functional Dimensions on page 33)
Value
Set the URV as the level above the bottom of the vessel (see Functional Dimensions on
page 33) in the units system selected with Function 4.1. 1 . It corresponds to an output
current of 20 mA.
1.6: Level LRV (F = 0 m)
Empty scale of level (see Functional Dimensions on page 33)
Value
Set the LRV as the level above the bottom of the vessel (see Functional Dimensions on
page 33) in the units system selected with Function 4.1. 1 . It corresponds to an output
current of 4 mA.