The following program reads Pr. 7 "Acceleration time" of the station 1 inverter to output to D1.
● Pr. 7 "Acceleration time" reading instruction code: H07 (hexadecimal)
● Refer to page A-5 for details of the parameter instruction code.
● The reply code (RWr10) to the instruction code execution is set in D2.
(Refer to page 5-756 for the reply code (RWr10).)
SB49
SW0B0.0
0
M0
X20
3
M300
7
M301
X1025
9
M302
X1025
16
24
Fig. 5-378:
Programming example 5
NOTE
For the parameter assigned the number of 100 or higher, change the link parameter extended set-
ting (set it to the one other than H00). Refer to page A-5 for the settings.
FR-A800
Check the data link status of the station 1.
M0
PLS M300
SET M301
Write the Pr. 7 read code (H07) to RWw10.
MOV H7
W110
Turn ON the instruction code execution request (RY25).
SET Y1025
RST M301
SET M302
Read the acceleration time (RWr11) and the reply code (RWr10)
MOV W11 D1
to output to D1 and D2 when the instruction code execution
completion (RX25) turns ON.
MOV W10 D2
Turn OFF the instruction code execution request (RY25).
RST Y1025
RST M302
END