Pressure transmitter series 2000t
Hide thumbs Also See for 265Ax:

Advertisement

Quick Links

SIL-Safety Instructions
Pressure Transmitter Series 2000T and
SM 265/7/9 SIL-EN Rev. 02
265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx
Instructions for Functional Safety

Advertisement

Table of Contents
loading

Summary of Contents for ABB 265Ax

  • Page 1 SIL-Safety Instructions Pressure Transmitter Series 2000T and SM 265/7/9 SIL-EN Rev. 02 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx Instructions for Functional Safety...
  • Page 2: Table Of Contents

    Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table of contents Page Field of application ............3 User benefits .
  • Page 3: Field Of Application

    Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Field of application Differential pressure, gauge pressure and absolute pressure measurements that shall meet the special safety requirements according to IEC 61508/ IEC 61511-1.
  • Page 4: Relevant Standards

    Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Relevant standards Standard Designation IEC 61508, Functional safety of electrical/electronic/programmable electronic safety-related systems (Target group: Part 1 to 7 Manufacturers and Suppliers of Devices) IEC 61511, Functional safety –...
  • Page 5 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety IMPORTANT This documentation applies to the transmitter 265xx as a part of a safety function. The following table shows the reachable Safety Integrity Level (SIL) of the entire safety-related system for systems of type B, depending on the safe failure fraction (SFF) and the hardware fault tolerance (HFT).
  • Page 6: Specifications For The Safety Function

    Defective transmitters / assembly groups should be returned to the ABB service and repair department, possibly with the type of malfunction and possible reason stated. When ordering spare parts or spare units please indicate the serial number (S/N) and year of manufacture of the original device.
  • Page 7: Settings

    11 Settings 11.1 Alarm behavior and current output In case of a malfunction the current is set to the selected value. The settings can be made via the ABB user interface DSV401 (SMART VISION) or via a hand-held terminal. NOTICE Check the safety function upon entry of all parameters.
  • Page 8 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 12.2 Specific safety-related characteristics λ λ λ Transmitter type Measuring range PFDav dd + 2010TD 10 mbar 75 % 8.54 × 10...
  • Page 9: Sil Conformity Declaration

    Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 13 SIL conformity declaration...
  • Page 10 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety...
  • Page 11: Management Summary

    Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 14 Management summary FMEDA and Prior-use Assessment Project: Pressure Transmitter 2600T / 2000T Series with 4..20 mA output Customer: ABB Automation Products GmbH...
  • Page 12 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Management summary This report summarizes the results of the hardware assessment with prior-use consideration according to IEC 61508 / IEC 61511 carried out on the pressure transmitter 2600T / 2000T Series with 4..20 mA output and software version V0.24.
  • Page 13 The prior-use investigation was based on field return data collected and analyzed by ABB Automation Products GmbH. This data cannot cover the process connection. The prior-use justification for the process connection still needs to be done by the end-user.
  • Page 14 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 2: Summary for version V1.1 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 15 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 4: Summary for version V1.2 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 16 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 6: Summary for version V2.1 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 17 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 8: Summary for version V2.2 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 18 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 10: Summary for version V3 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 19 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 12: Summary for version V4 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 20 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety Table 14: Summary for version V5 – Failure rates Fail-safe state = Fail-safe state = Failure category (Failure rates in FIT) “fail high”...
  • Page 21 Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety The boxes marked in yellow ( ) mean that the calculated PFD values are within the allowed range for SIL 2 according to table 2 of IEC 61508-1 but do not fulfill the requirement to not claim more than 35% of this range, i.e.
  • Page 22 ABB has Sales & Customer Support The Company’s policy is one of continuous product expertise in over 100 countries worldwide. improvement and the right is reserved to modify the information contained herein without notice. www.abb.com Printed in the Fed. Rep. of Germany (05.2007) ©...

This manual is also suitable for:

265gx265vx265dx265jx267cx269cx

Table of Contents