TROUBLE SHOOTING WHEN THE TIMER LAMP BLINKS
MODEL RAF-25RPA, RAF-35RPA
When the timer lamp on the display section of the indoor unit blinks, refer to the following table.
Lamp blinking mode
2 sec.
2 sec.
2 sec.
2 sec.
2 sec.
2 sec.
2 sec.
2 sec.
(
Lights for 0.35 sec. at
interval of 0.35 sec.
〈Cautions〉
(1) If the interface circuit is faulty when power is supplied, the self-diagnosis display will not be displayed.
(2) If the indoor unit does not operate at all, check if the connecting cable is connected to the outdoor unit.
ONCE
Reversing valve defective
2 Times
Forced operation of outdoor unit
3 Times
Indoor/Outdoor interface defective
4 Times
Outdoor defective indication
9 Times
Indoor sensor defective
10 Times
Abnormal rotating numbers of DC fan motor
12 Times
Interface voltage error
13 Times
IC401 defective
)
Main defective