7.3 Common Bell (Figure 7-3)

A customer-provided loud ringing device can be controlled by the general-purpose dry contact of
the DCS-816 system by means of the relevant MMC. Note that the dry contact is rated 24VDC, 1
Amp. The system requires MDF connection for the dry contact and the connection can be made
through the Champ connector. See Figure 2-3 and refer to section 2.5 (MDF Cabling).
Using one pair twisted wires, connect a customer-provided loud bell to the general-purpose dry
contact via the Champ connector on the base board.
25 PAIR CABLE WITH FEMALE CONNECTOR TO THE BASE CHAMP CONNECTOR

CONNECTING AN EXTERNAL LOUD BELL

CHAMP CONNECTION
PIN COLOUR
36/11BK-GR/ GR-BK T/R, GP Dry Contact
NO POLARITY
CONNECT AN EXTERNAL LOUD BELL TO THE
INTERFACE VIA MDF
THE CONTACT IS RATED 24VDC- 1A