Power - Motorola Piccolo-XR Owner's Manual

Distributed i/o systempiccolo interface unit (piu) and piccolo-xr unit
Table of Contents

Advertisement

APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS
Radio Transmission
Radio Off
(TX power-10mW)
(TX power-100mW)
Radio Receives
Sleep Mode
LPM0
LPM3
Power Fail Mode
LPM3
Power Monitors
Power In Report
Power OK Voltage
Low Power Voltage
Very Low Battery
Reverse Input Voltage
Connection
Note 6: Power In = 4 V DC, Radio (On Board Circuits) = Off,
internal Radio is off.
Note 7: Power In = 7.8 V DC, Radio (On Board Circuits) =
Off, internal Radio is off.
Note 8: Power In = 5.5 V DC, Radio (On Board Circuits) =
On, internal Radio is On.
Note 9: Power In = 7.8 V DC, Radio (On Board Circuits) =
On, internal Radio is On.
Note 10: Apply 1.2 KHz FM signal with 2 KHz Deviation,
Sensitivity @-110 dBm to the radio, and read BER. At
extreme temperatures apply -104 dBm.
44
1.2 – 1.5 mA (See Notes 6, 7 p. 44.)
65 – 90 mA (See Notes 8, 9 p. 44.)
100 – 150 mA (See Notes 8, 9 p. 44.)
30 – 40 mA
(See Notes 8, 9 p. 44.)
190 – 250 μA (See Note 7 p. 44.)
40 – 65 μA
40 – 70 μA
 200 mV
Service Toolkit Adjustable
Default = 6 V DC  200 mV
Service Toolkit Adjustable
Default = 5 V DC  200 mV
Service Toolkit Adjustable
Default = 4.8 V DC  200 mV
Protected
(See Note 7 p. 44.)
(See Note 6 p. 44.)