Hitachi F400 Hardware Reference Manual
Hitachi F400 Hardware Reference Manual

Hitachi F400 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for F400:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform
F400 and F600
83-04-4x or later
Hardware Reference Guide
This guide describes the hardware features and specifications of the Hitachi Virtual Storage
Platform F400 and the Hitachi Virtual Storage Platform F600 all-flash arrays.
MK-94HM8045-09
October 2017

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi F400

  • Page 1 Hitachi Virtual Storage Platform F400 and F600 83-04-4x or later Hardware Reference Guide This guide describes the hardware features and specifications of the Hitachi Virtual Storage Platform F400 and the Hitachi Virtual Storage Platform F600 all-flash arrays. MK-94HM8045-09 October 2017...
  • Page 2 Licensee may not make any other copies of the Materials. "Materials" mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3 Changes in this revision..................10 Document conventions................... 10 Conventions for storage capacity values..............11 Accessing product documentation................12 Getting help......................12 Comments......................12 1 Hitachi Virtual Storage Platform F400, F600 hardware overview....13 Block configuration....................15 Unified configuration....................15 VSP F400 model.....................15 VSP F600 model.....................17 Features........................ 19 Scalability......................
  • Page 4 VSP F400 and VSP F600 mechanical specifications............56 B Electrical specifications for VSP F400, F600..........61 Electrical specifications................... 62 C Environmental specifications for VSP F400, F600........63 Environmental specifications................... 64 D iSCSI standards and specifications............67 iSCSI standards......................68 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 5 APAC and EMEA single-phase PDU 1P32A-18C13-3C19CE.P........97 APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P......... 98 APAC and EMEA three-phase PDU 3P16A-15C13-3C19CE.P........98 APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P........99 J Regulatory compliance............... 101 Index....................103 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 6 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 7: Preface

    Preface This guide describes the hardware features and specifications of the Hitachi Virtual Storage Platform F400, F600 all-flash arrays. Intended audience □ Safety and environmental notices □ Product version □ Release notes □ Changes in this revision □ Document conventions □...
  • Page 8: Intended Audience

    Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
  • Page 9: Product Version

    Product version This document revision applies to the following product versions: • VSP F400, F600 firmware 83-04-4x or later Preface Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 10: Release Notes

    • Hitachi Storage Virtualization Operating System (SVOS) 7.2 or later • Hitachi NAS firmware version 13.1 or later Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document.
  • Page 11: Conventions For Storage Capacity Values

    Logical capacity values (for example, logical device capacity, cache memory capacity) are calculated based on the following values: Logical capacity unit Value 1 block 512 bytes 1 cylinder Mainframe: 870 KB Open-systems: Preface Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 12: Accessing Product Documentation

    Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical support, log on to Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community...
  • Page 13: Hitachi Virtual Storage Platform F400, F600 Hardware Overview

    Hitachi Virtual Storage Platform F400, F600 hardware overview Hitachi Virtual Storage Platform F400, F600 are modular, rack-mountable, all- flash arrays that deliver high performance, high reliability, and flash- accelerated scalability. The storage system contain dual controllers, each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and iSCSI and Fibre Channel I/O modules.
  • Page 14 Features □ Scalability □ Hitachi Virtual Storage Platform F400, F600 hardware overview Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 15: Block Configuration

    • One or more drive trays for block-level storage • One 1U block service processor server (SVP) VSP F400 model The VSP F400 is a highly reliable all-flash system that offers high storage capacity with full redundancy to better protect data and manage storage operations.
  • Page 16 FMD HD DKC-F810I-7R0FP 7 TB FMD HD DKC-F810I-14RFP 14 TB Solid-state drives The VSP F400 storage system supports up to 384 SSDs. The total raw flash capacity is 1,451 TB. Model number Drive type Drive capacity DKC-F810I-1R9MGM 1.9 TB DKC-F810I-3R8MGM 3.8 TB...
  • Page 17: Vsp F600 Model

    DW-F800-DBF 5.25-inch FMD 2U (86.2 mm) SFF drive tray • DW-F800-DBS 2.5-inch SFF 2U (86.2 mm) (power supply, contains BNST) • DW-F800- DBSC Hitachi Virtual Storage Platform F400, F600 hardware overview Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 18 12 (NAS modules installed) 56 (NAS modules not installed) DW-F800-4HF32R 32/16-Gbps Fibre Channel (4- port) front-end module 24 (NAS modules installed) Hitachi Virtual Storage Platform F400, F600 hardware overview Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 19: Features

    Features The features described in the table are included with VSP F400 and VSP F600. Feature Value Maximum cache memory supported VSP F400: 128 GB VSP F600: 256 GB Maximum number of spare drives Maximum number of RAID groups Maximum volume size...
  • Page 20: Examples Of Supported Vsp F600 Configurations

    Maximum number of VSP F600 controller Drive trays trays drives CBLM 288 FMDs (HAF) 48 FMDs 16 FMDs + 1 spare (DC2) 576 SSDs Hitachi Virtual Storage Platform F400, F600 hardware overview Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 21: Virtual Storage Platform F400, F600 Controller

    Virtual Storage Platform F400, F600 controller The Virtual Storage Platform F400, F600 models are equipped with dual controllers for communicating with a data host. Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans.
  • Page 22: Cblm Controller

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. ALARM LED Off: Normal operation. Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 23: Cblm Front Panel Leds (Without Bezel)

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. Controller 1 (bottom) and Controllers Controller 2 (top). Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 24: Cblm Rear Panel

    (for example, BKMF-10 and BKMF-20). CBLM rear panel The following table describes the definitions of the CBLM controller rear panel LEDs. Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 25 Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 26: Cblm Power Supply Unit Leds And Connectors

    LEDs display the operating status of the storage system. Front end module descriptions The front end module LEDs display the operating status of the module. Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 27: Gbps Iscsi Board Leds And Connectors (Optical)

    Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet LAN cables. 10-Gbps iSCSI board LEDs and connectors (copper) Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 28 Off: No link connection or not ready to communicate. iSCSI connectors Connect to Ethernet LAN cables. 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 29 PORT LED Red: Small form factor pluggable can be removed. Blue: Normal link status at 16- Gbps (16-Gbps). Blue: Normal link status at 32- Gbps (32-Gbps). Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 30: Gbps Fibre Channel (2-Port) Board Leds And Connectors

    Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H 16-Gbps Fibre Channel (2-port) board LEDs and connectors Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 31: Lan Blade Leds And Connectors

    Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H LAN blade LEDs and connectors Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 32: Back End Module Leds And Connectors

    Red: LAN blade can be removed. Uninterruptible power supply (UPS) port Back end module LEDs and connectors The back end module LEDs display the operating status of the module. Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 33 Port LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 34 Virtual Storage Platform F400, F600 controller Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 35: Storage System Drive Trays

    IOP performance across all host connection ports, conventional HDDs are not included or configurable with all-flash arrays. Flash module drive (FMD) tray □ Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 36: Flash Module Drive (Fmd) Tray

    Can be turned on or turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. FMD front panel without bezel Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 37 FMDs. POWER, READY, and LOCATE LEDs Green: Drive tray is powered Green: Drive tray is operational. Amber: • Indicates the location of the chassis. Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 38: Fmd Rear Panel

    PATH (IN) LED Blue: IN side port is linked up. PATH (IN) connector Connects to a controller or drive tray. Blue: OUT side port is linked PATH (OUT)LED Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 39 Three LEDS, top to bottom: operating normally. RDY LED Green: Power supply unit is AC IN LED operating normally. ALM REPLACE LED Red: Power supply unit can be replaced. Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 40 Storage system drive trays Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 41: Host Port Expansion Chassis

    Host port expansion chassis front panel bezel LEDs □ PCIe switchboard □ Host port expansion chassis fan □ PCIe cable connector □ Host port expansion chassis power supply □ Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 42: Host Port Expansion Chassis Front Panel Bezel Leds

    Green: Host port expansion is POWER LED turned on. Amber: PCIe module is turned Off: PCIe module is turned off. Lock or unlock the front bezel. Safety lock PCIe switchboard Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 43: Host Port Expansion Chassis Fan

    Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 44 Off: Basic PCIe is normal or not set. Link Option LED Green: Option PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 45: Host Port Expansion Chassis Power Supply

    Number Item Description ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 46 Host port expansion chassis Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 47: Nas Module

    NAS module The NAS module provides communication ports to support file system protocols in a block- or file-system configuration. NAS Module Ports and LEDs □ NAS module Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 48: Nas Module Ports And Leds

    Reserved for future use Status LED Green NAS modules are functioning normally. NAS modules can be removed. Link LED Blue Displays link status. Fail LED A failure has occurred. NAS module Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 49: Vsp Service Processor Server

    The SVP is available as: • A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7. • A software application that runs Windows 7 Professional x64 Service Pack 1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host, or Linux KVM host.
  • Page 50: Service Processor Description

    • Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button.
  • Page 51: Svp Rear Panel

    LAN ports. Number Description Power socket. Attach the power cable supplied with the SVP. Four LAN ports arranged as follows: LAN3 LAN4 LAN1 LAN2 VSP service processor server Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 52: Service Processor Hardware Specifications

    2 TB Network interface card x4 ports (on-board NIC) + x1 IPMI (BMC) port Fans 2 x 4-cm 4-pin PWM fans Operating system Windows Embedded Standard 7 VSP service processor server Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 53: Maintaining The Storage System

    For more complex maintenance activities, contact customer support. Storing the storage system □ Powering off the storage system □ Maintaining the storage system Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 54: Storing The Storage System

    To avoid this situation, charge the battery for more than three hours at least once every six months. Maintaining the storage system Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 55: A Mechanical Specifications For Vsp F400, F600

    Mechanical specifications for VSP F400, F600 The storage system mechanical specifications are described for VSP F400, F600 . VSP F400 and VSP F600 mechanical specifications □ Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 56: Vsp F400 And Vsp F600 Mechanical Specifications

    5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm) tray) Data capacity (GB) Component Specification Flash Module Drive (flash module drive tray) 1759.21, 3518.43 , 7036.87, 14073.74 GB Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 57: Battery Specifications

    32-Gbps Fibre Channel optical (4-port) 10-Gbps optical iSCSI 10-Gbps copper iSCSI 8-Gbps Fibre Channel optical Number of ports (NAS Module not installed) 16-Gbps Fibre Channel optical (2-port) Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 58: Raid Specifications

    VSP F600:240 Maximum volume size 3 TB (or 4 TB when using the LDEVs of other storage systems) Maximum volumes/host groups and iSCSI 2048 targets Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 59 The table lists the values of a maximum configuration when all controllers and drives are mounted. Component Specification CBLM 187.39 pounds (85 kg) Required height Component Specification CBLM Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 60 3 hours every six months. Insulation performance Item Specification Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more Mechanical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 61: B Electrical Specifications For Vsp F400, F600

    Electrical specifications for VSP F400, F600 The electrical specifications are described for the storage systems. Electrical specifications □ Electrical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 62: Electrical Specifications

    This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Electrical specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 63: C Environmental Specifications For Vsp F400, F600

    Environmental specifications for VSP F400, F600 The environmental specifications are described for the storage systems. Environmental specifications □ Environmental specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 64: Environmental Specifications

    5.0 or less at 5 Hz to 300 Hz (no damage to product) 9.8 (1.0 G) Within 5 seconds (resonance point: 10 Hz or less) Environmental specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 65: Acoustic Noise

    Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient temperature, drive configuration, and operating status. Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply. Environmental specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 66 Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Environmental specifications for VSP F400, F600 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 67 The following tables describe the standards and specifications for using iSCSI in a hosting environment. iSCSI standards □ iSCSI specifications □ iSCSI standards and specifications Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 68: Iscsi Standards

    Path I/O) Link 10 Gbps SFP+ Transfer speed 10 Gbps Connector type Cable Optical OM3, OM2 MMF cable Network switch L2 or L3 switch Should comply with IEEE802.3ae iSCSI standards and specifications Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 69 The setting of the corresponding host should also be changed to log in the new port number. • The new port number might conflict with other network communication or be iSCSI standards and specifications Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 70 Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef iSCSI standards and specifications Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 71: E Replacement Parts

    Replacement parts Part replacement is essential for maintaining the high performance of the system. Replacing system components is covered by the maintenance service contract. Battery unit □ Replacement parts Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 72: Battery Unit

    If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery. Replacement parts Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 73: F Data And Power Cables

    The storage system supports a variety of data and power cables for specific hosting environments. Fibre Channel cables □ iSCSI cables □ Managing data cables □ AC power cables □ Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 74: Fibre Channel Cables

    If this default value is set, Fabric is set to ON automatically. Note: To connect to the server by the 16-Gbps direct connection, the Fabric Emulation function of the Hitachi host adapter is required. Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 75 Gbps. If this default value is set, Fabric is set to ON automatically. Note: The five Hitachi FC HBAs also have an alternate option of Fabric Emulation. When the HBA is configured to use this mode, treat it as an attached switch and set the storage port to Fabric = On and Connection Type = P-to-P.
  • Page 76 One side Other side LC-LC cable Optical Equivalent to 50, 125 μm, LC connector LC connector (shortwave) DXLC-2P-PC- 62.5, 125 μm xxM-GC50, Multimode Wavelength: 125-2SR 850 nm (OMx) Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 77: Iscsi Cables

    • Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows iSCSI cables When constructing an iSCSI system with a direct connection or switch connection, consider the following: Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 78 The following figure shows the type of optical connector that connects the storage system optical iSCSI ports. • LC connector type • Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 79: Managing Data Cables

    1.73 inch (40 mm) Protecting cables Damage to your Fibre Channel and Ethernet cables can affect the performance of your storage system. Observe the following guidelines to protect cables Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 80 When cabling full-width modules, such as NAS modules as shown in the following figure, route the cables horizontally, so that they do not interfere when replacing a module. Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 81: Ac Power Cables

    AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended.
  • Page 82 Also Malaysia and Ireland. Also known as "Schuko" connector and used in Austria, Belgium, Finland, France, Germany, Greece, Hungary, Indonesia, Netherlands, Norway, Poland, Portugal, Russia, Spain, and Sweden. Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 83: Ac Connections

    1 ANSI C73.11 2 NEMA 6-15P 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 BS-1363 200V-240V 5 BS 1365 3IEC 83 Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 84: Power Cable Usage Guidelines

    6 AS C112 Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: •...
  • Page 85: Cable Management

    These straps, shown in the following image, loop around the neck of a power cable connector, and the notched tail is slipped over the hook of the restraining bar fixed to the storage system. Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 86 Data and power cables Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 87: G Port Address Mapping

    Port address mapping Port address mapping □ Port address mapping Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 88: Port Address Mapping

    HBA, the host might not be able to recognize the VOL. If this problem or other problems occur, revert to the default value of EF. * A value set as the default value. Port address mapping Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 89 Third-party rack support for VSP Fx00 models □ Hitachi Universal V2 Rack rail kits □ Hitachi Universal V2 Rack accessories □ Third-party rack support for DB60 dense intermix drive trays □ Third-party racks Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 90: Third-Party Rack Support For Vsp Fx00 Models

    PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
  • Page 91: Third-Party Rack Support For Db60 Dense Intermix Drive Trays

    • Dense tray rail kits require square mounting holed racks. • Use a ladder to service the DB60 dense intermix drive tray if the drive tray is mounted above shelf height RU32. Third-party racks Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 92 Third-party racks Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 93 Hitachi Universal V2 Rack power distribution units The Hitachi Universal V2 Rack is equipped with specific power distribution units (PDU) for Americas, APAC, and EMEA regions. The PDUs can provide electrical power to the storage system in a single-phase or three-phase configuration.
  • Page 94: Americas Single-Phase Pdu 1P30A-8C13-3C19Ul.p

    Americas single-phase PDU 1P30A-8C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 1 Americas PDU for the Hitachi Universal V2 Rack (Single-phase PDU 1P30A-8C13-3C19UL.P) Part Number Region Phase Description 1P30A-8C13-3C19UL.P Americas Single • 208V, 30A (24A rated) 60Hz •...
  • Page 95: Americas Three-Phase Pdu 3P30A-8C13-3C19Ul.p

    • 4.5 m (14.76 feet) cable Americas three-phase PDU 3P30A-8C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 3 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-8C13-3C19UL.P) Part Number Region Phase Description 3P30A-8C13-3C19UL.P...
  • Page 96: Americas Three-Phase Pdu 3P30A-24C13-6C19Ul.p

    Figure 4 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-15C13-3C19UL.P) Part Number Region Phase Description 3P30A-15C13-3C19UL. Americas Three • 208V 3P, 30A (24A rated) 60Hz • 15 IEC C13 + 3 IEC C19 sockets • NEMA L15-30P input power plug •...
  • Page 97: Apac And Emea Single-Phase Pdu 1P32A-9C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P The following figure and table describes the specifications of the PDU. Figure 6 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single- phase 1P32A-9C13-3C19CE.P) Part Number Region Phase Description 1P32A-9C13-3C19CE.P APAC and EMEA Single •...
  • Page 98: Apac And Emea Three-Phase Pdu 3P16A-9C13-3C19Ce.p

    4.5 m (14.76 feet) cable APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P The following figure and table describes the specifications of the PDU. Figure 8 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three- phase 3P16A-9C13-3C19CE.P) Part Number Region...
  • Page 99: Apac And Emea Three-Phase Pdu 3P32A-24C13-6C19Ce.p

    Figure 9 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three- phase 3P16A-15C13-3C19CE.P) Part Number Region Phase Description 3P16A-15C13-3C19CE. APAC and EMEA Three • 400V max. 3x 16A 50Hz / 60Hz • 15 IEC C13 + 3 IEC C19 sockets •...
  • Page 100 Hitachi Universal V2 Rack power distribution units Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 101: Regulatory Compliance

    EN61000-3.2:2006+A1 EN61000-3.3:2008 Safety certifications UL and CSA cTUVus USA and Canada 60950-1:2007 EN60950-1:2006+A1 Germany IEC60950-1:2005+A1 All CB countries IEC60950-1:2005+A1 S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan Regulatory compliance Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 102 Product marking or Standard Specification Country regulation logo EN60950-1:2006+A1 Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Regulatory compliance Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 103: Index

    24 flash module drive tray 36 with front panel bezel 22 host port expansion chassis 42 chassis 41 compliance 101 configuration 15 configurations 19, 20 connections AC 83 Index Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 104 LEDs 43 PCIe switchboard storing the storage system 54 LED 42 supported configurations 19, 20 physical SVP SVP 49 rear panel 51 hardware specifications 52 ports 26 power cable assemblies 81 Index Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 105 DB60 dense intermix drive tray 91 third-party racks 89 third-party racksmounting guidelines 90 Unified 15 Virtual Storage Platform F400, F600 21 without front panel bezel 23 Index Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 106 Index Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 107 Hitachi Virtual Storage Platform F400, F600 Hardware Reference Guide...
  • Page 108 Hitachi Vantara Corporate Headquarters Regional Contact Information 2845 Lafayette Street Americas: +1 866 374 5822 or info@hitachivantara.com Santa Clara, CA 95050-2639 USA Europe, Middle East and Africa: +44 (0) 1753 618000 or info.emea@hitachivantara.com www.HitachiVantara.com Asia Pacific: +852 3189 7900 or info.marketing.apac@hitachivantara.com...

This manual is also suitable for:

F600

Table of Contents