Fine Tuning Functions - Hitachi SJ700 series Manual

Powerful inverter with sensorless vector control
Hide thumbs Also See for SJ700 series:
Table of Contents

Advertisement

● B GROUP: FINE TUNING FUNCTIONS
Code
Function Name
b001
Selection of restart mode
b002
Allowable under-voltage power failure time
b003
Retry wait time before motor restart
Instantaneous power failure/under-voltage
b004
trip alarm enable
Number of restarts on power
b005
failure/under-voltage trip events
b006
(Input) Phase loss detection enable
b007
Restart frequency threshold
b008
Selection of retry after tripping
b009
Selection of retry after undervoltage
Selection of retry count after overvoltage
b010
or overcurrent
b011
Retry wait time after tripping
Electronic thermal setting (calculated within
b012
the inverter from current output)
Electronic thermal setting (calculated within
b212
the inverter from current output), 2nd motor
Electronic thermal setting (calculated within
b312
the inverter from current output), 3rd motor
b013
Electronic thermal characteristic
b213
Electronic thermal characteristic, 2nd motor
b313
Electronic thermal characteristic, 3rd motor
b015
Free-setting electronic thermal frequency (1)
b016
Free-setting electronic thermal current (1)
b017
Free-setting electronic thermal frequency (2)
b018
Free-setting electronic thermal current (2)
b019
Free-setting electronic thermal frequency (3)
b020
Free-setting electronic thermal current (3)
b021
Overload restriction operation mode
b022
Overload restriction setting
b023
Deceleration rate at overload restriction
b024
Overload restriction operation mode (2)
b025
Overload restriction setting (2)
b026
Deceleration rate at overload restriction (2)
b027
Overcurrent suppression enable
Active frequency matching,
b028
scan start frequency
b029
Active frequency matching, scan-time constant
Active frequency matching,
b030
restart frequency select
b031
Software lock mode selection
b034
RUN/ power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
b039
Automatic user-parameter setting function enable
(*1) 4000HF:5.0 (*2) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz) (*3) 4000HF:0. to 120. (Hz) (*4) SJ700-2:04. (basic display) (*5) SJ700-2:01
17
Monitored data or setting
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03
(tripping after deceleration and stopping with matching frequency), 04 (restarting
with active matching frequency)
0.3 to 25.0 (s)
0.3 to 100.0 (s)
00 (disabling), 01 (enabling), 02 (disabling during stopping and decelerating to
stop)
00 (16 times), 01 (unlimited)
00 (disabling), 01 (enabling)
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03
(tripping after deceleration and stopping with matching frequency), 04 (restarting
with active matching frequency)
00 (16 times), 01 (unlimited)
1 to 3 (times)
0.3 to 100.0 (s)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
0. to (b017) (Hz)
0.00 to rated current (A)
(b015) to (b019) (Hz)
0.00 to rated current (A)
(b017) to 400. (*3)
0.00 to rated current (A)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling
during constant speed), 03 (enabling during acceleration and deceleration
(increasing the speed during regeneration))
SJ700/SJ700D (CT): 0.20 x "rated current" to 2.00 x "rated current" (A)
< 75kW and over:0.20 x 1.80 >
SJ700D (VT)/SJ700B: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling
during constant speed), 03 (enabling during acceleration and deceleration
(increasing the speed during regeneration))
SJ700/SJ700D (CT): 0.20 x "rated current" to 2.00 x "rated current" (A)
< 75kW and over:0.20 x 1.80 >
SJ700D (VT)/SJ700B: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling)
SJ700/SJ700D (CT): 0.20 x "rated current" to 2.00 x "rated current" (A)
< 75kW and over:0.20 x 1.80 >
SJ700D (VT)/SJ700B: 0.20 x "rated current" to 1.50 x "rated current" (A)
0.10 to 30.00 (s)
00 (frequency at the last shuto ), 01 (maximum frequency), 02 (set frequency)
00 (disabling change of data other than "b031" when SFT is on), 01 (disabling
change of data other than "b031" and frequency settings when SFT is on),
02 (disabling change of data other than "b031"), 03 (disabling change of data
other than "b031" and frequency settings), 10 (enabling data changes during
operation)
0. to 9999. (0 to 99990), 1000 to 6553 (10000 to 655300) (hr)
00 (enabling both forward and reverse rotations), 01 (enabling only forward
rotation), 02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to 255 (maximum reduced voltage start
time)
00 (full display), 01 (function-specific display), 02 (user setting), 03 (data
comparison display), 04 (basic display)
SJ700D: 000 (Func code that STR key pressed last displayed), 001 to 060 (d001
to d060), 201 (F001)
SJ700/SJ700B: 00 (screen displayed when the STR key was pressed last), 01
(d001), 02 (d002), 03 (d003), 04 (d007), 05 (F001)
00 (disabling), 01 (enabling)
[⃝ = Allowed
Default Setting
SJ700/SJ700D(CTmode)
SJ700B
(allowed or not)
-FE
-FU
-F
-F
-FU
00
00
00
00
00
1.0
1.0
1.0
1.0
1.0
1.0 (*1) 1.0 (*1) 1.0 (*1)
1.0
1.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
0.00
0.00
0.00
0.00
0.00
00
00
00
00
00
00
00
00
00
00
3
3
3
3
3
1.0 (*1) 1.0 (*1) 1.0 (*1)
1.0
1.0
Rated current of
inverter x 1.00
01
01
00
01
01
01
01
00
01
01
01
01
00
01
01
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
0.
0.
0.
0.
0.
0.0
0.0
0.0
0.0
0.0
01
01
01
01
01
Rated current
Rated current x 1.50
x 1.20
1.00
1.00
1.00
1.00
1.00
01
01
01
01
01
Rated current
Rated current x 1.50
x 1.20
1.00
1.00
1.00
1.00
1.00
01
01
01
01
01
Rated current of inverter x 1.00
0.50
0.50
0.50
0.50
0.50
00
00
00
00
00
01
01
01
01
01
0.
0.
0.
0.
0.
00
00
00
00
00
06
06
06
06
06
00
00
00
04
04
(*4)
(*4)
(*4)
001
001
001
01
01
(*5)
(*5)
(*5)
00
00
00
00
00
×
= Not permitted]
Setting
Change
during
during
operation
operation
(allowed or not)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×