User interfaces (API)
7.8 Data types
7.8.7.14

EPullOrPlugEventType

Description
This enumeration contains predefined types of pull/plug events for S7 modules.
Table 7- 456 EPullOrPlugEventType - Native C++
Syntax
Table 7- 457 EPullOrPlugEventType - .NET (C#)
Syntax
7.8.7.15
EProcessEventType
Description
This enumeration contains predefined types of process events for S7 modules.
Table 7- 458 EProcessEventType - Native C++
Syntax
344
enum EPullOrPlugEventType
{
SR_PPE_UNDEFINED = 0,
SR_PPE_PULL_EVENT = 1,
SR_PPE_PLUG_EVENT = 2,
SR_PPE_PLUG_EVENT_ERROR_REMAINS = 3,
SR_PPE_PLUG_WRONG_MODULE_EVENT = 4
};
enum EPullOrPlugEventType
{
Undefined = 0,
Pull = 1,
Plug = 2,
PlugErrorRemains = 3,
PlugWrongModule = 4
}
enum EProcessEventType
{
SR_PET_UNDEFINED = 0,
SR_PET_RISING_EDGE = 1,
SR_PET_FALLING_EDGE = 2,
SR_PET_LIMIT1_UNDERRUN = 3,
SR_PET_LIMIT1_OVERRUN = 4,
SR_PET_LIMIT2_UNDERRUN = 5,
SR_PET_LIMIT2_OVERRUN = 6
};