3.1

Technical specifications

Connections
Attachment of end devices or network components over twisted
pair
SCALANCE S602/S612
SCALANCE S623
SCALANCE S627-2M
Connector for power supply
Connector for signaling contact
Electrical data
Power supply
Typical power consumption at 24 VDC, 1000 Mbps
SCALANCE S602/S612
SCALANCE S623
SCALANCE S627-2M
Max. current consumption at rated voltage
SCALANCE S602/S612
SCALANCE S623
SCALANCE S627-2M
Permitted cable lengths
Connection over Industrial Ethernet FC TP cables
0 - 100 m
0 - 85 m
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
10/100/1000 Mbps (half/full duplex)
2 x RJ-45 jacks with MDI-X assignment
3 x RJ-45 jacks with MDI-X assignment
3 x RJ-45 jacks with MDI-X assignment
2 x media modules slots each for one 2-port media
module
1x4-pin plug-in terminal block
1x2-pin plug-in terminal block
Supply 24 VDC (19.2 to 28.8 VDC)
Implemented redundantly
Safety extra-low voltage (SELV)
9.0 W
9.7 W
12.0 W without media modules / max. 2.5 W extra per
media module
0.5 A
0.5 A
0.7 A
Industrial Ethernet FC TP standard cable with
IE FC RJ-45 plug 180
or
Over Industrial Ethernet FC outlet RJ-45 with 0 - 90 m
Industrial Ethernet FC TP standard cable + 10 m
TP cord
Industrial Ethernet FC TP marine/trailing cable with
IE FC RJ-45 plug 180
or
0 - 75 m Industri-
al Ethernet FC TP marine/trailing cable + 10 m
TP cord
3
11