Problem
Although the VSN300
board has been installed
correctly in "Station Mode"
and works correctly on the
local network, no data has
been transmitted to the
Aurora Vision®
It is not possible to access
the WUI of the board when
the board is operating in
"Station Mode – DHCP"
E
vent codes
Possible causes
The MAC address used to register
the logger on the Aurora Vision®
platform is not the same as the actual
address associated with the VSN300
board which is installed
The Wi-Fi network to which the
VSN300 board is connected, could
be protected by a Firewall which
prevents the remote exchange of data
with the Aurora Vision® platform
An incorrect dynamic IP address is
being used to access the WUI or the
IP address could have been modified
by the Wi-Fi router to which the bard
is connected
Wi-Fi board events
Event code
I003
I005
W017
W018
W019
W020
W021
W022
W023
W024
W026
W030
W031
E030
Inverter events
Event code
W502
E501
Solution
Make sure that the MAC address registered on the
Aurora Vision® platform is actually the one associated
with the VSN300 board installed. If it is not, modify the
registered MAC address
Contact the network administrator in order to have
the Firewall configured so that the remote exchange
of data between the VSN300 board and the Aurora
Vision® platform is allowed
Access the WUI of the VSN300 board using its "Host
Name" (the DNS service must be enabled);
If possible, access the pages of the Wi-Fi router web
server to which the board is connected and read the
new dynamic IP address assigned to the VSN300
board
Switch off the Wi-Fi router to which the board is
connected so as to force the board to operate in "AP
mode". It will then be possible to access the internal
WUI via the static IP address 192.168.117.1 and,
once inside, configure the board in "Station Mode –
DHCP" taking note of the newly assigned dynamic IP
address
Event
New inverter identified
Start
Incorrect logger credentials
Incompatible access point
Wi-Fi not in the list
Wi-Fi not permitted
Problem with communication with the gateway
No internet connection
Wi-Fi network scan timed-out
Communication problems with the portal for the update
Clock not synchronised
Incorrect Wi-Fi password
Communication problems with the portal for data transmission
Poor Wi-Fi connection
Event
Production warning zero
Inverter communication error
- 68 -