Wired remote controller
Error mode
Contents
PFC overload error
Input current sensor error
IPM is over heated
Gas leak error
Capacities not matched
Option code miss matching
among the indoors(only for
DPM)
Inverter EEPROM loading error
Communication error between
the Hydro Unit and wired
remote controller
Communication tracking error
between the Hydro Unit and
wired remote controller
Wired remote controller
temp sensor SHORT or OPEN
Memory(EEPROM) Read
Write error(Wired remote
controller data error)
Water inlet (PHE) temp sensor
error (Short/Open)
Water outlet (PHE) temp
sensor error (Short/Open)
Water tank temp sensor error
(Short/Open)
Refrigerant gas inlet temp
sensor error (Short/Open)
Flow switch open error
Flow switch close error
Thermostat wrong connection
error
Mixing valve temp sensor error
(Short/Open)
Samsung Electronics
(cont.)
Check reactor located in control plate. If reactor is normal,
exchange INVERTER PBA.
Check Input current sensor on Inverter PCB
Check INVERTER PBA's temperature. Power off and cool
down INVERTER PBA, and then restart the outdoor unit.
Check the coolant charging status
Check the indoor EVA sensor
Check if the outdoor unit service value is open
Check that the indoor/outdoor installation pipe/wiring
are correct
Check the option code of the Control Kit
Option setting data is wrong.
(This error don't occur in EMF 150-AM).
Check EEPROM DATA.
Check the normal operation of PCB.
Check the Control Kit PBA and wired remote controller
Check the Control Kit PBA and wired remote controller
Check sensor connection status
Check the wired remote controller
Check sensor connection status.
Check sensor location. Check sensor resistance.
Check sensor connection status.
Check sensor location. Check sensor resistance.
Check sensor connection status.
Check sensor location.
Check sensor resistance.
Check sensor connection status.
Check sensor location. Check sensor resistance.
Check the junction point of Flow Switch terminal.
Check the junction point signal of Paddle operation after
the Flow Switch disassembly.
Check the water flow(Strainer clogging, Pump operation)
Check the junction point of Flow Switch terminal.
Check the junction point signal of Paddle operation after
the Flow Switch disassembly.
Check the water flow(Strainer clogging, Pump operation)
Check the wiring of Hydro Unit Thermostat.
Check the Cooling /Heating signal : Concurrent wiring or
not.
Check Control Kit Mixing Valve Outlet temperature sensor
location.
Measure
Product operation in
error condition
Error type
Outdoor unit/
Compressor/Control
Kit
Comp down
Operation Off
error
Comp down
Operation Off
error
Comp down
Operation Off
error
Self diagnostic
Operation Off
error
Outdoor unit
Operation Off
protection
control error
Comp down
Operation Off
error
Comp down
Operation Off
error
communication
Operation Off
error
communication
Operation Off
error
wired remote
Operation Off
controller
sensor error
communication
Operation Off
error
Indoor sensor
Operation Off
error
Indoor sensor
Operation Off
error
Indoor sensor
Operation Off
error
Indoor sensor
Operation Off
error
Comp down
Operation Off
error
Comp down
Operation Off
error
Indoor sensor
Operation Off
error
Indoor sensor
Operation Off
error