Page 2
Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
Page 9
This product must not be used in residential areas. This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Equipment with NEBS specifications In the Hitachi Virtual Storage Platform midrange family,, the VSP G200 equipment meets the Network Equipment-Building System (NEBS) specifications. The equipment with the NEBS specifications is suitable for use in Telecommunications Facilities. The equipment with the NEBS specifications is suitable for use in the Common Bonding Network (CBN).
Warns the user of a hazardous situation which, if not avoided, could result in death or serious injury. Conventions for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical support, log on to Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community...
Please send us your comments on this document to doc.comments@hds.com. Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you!
Hitachi Virtual Storage Platform G200 hardware overview The Hitachi Virtual Storage Platform G200 is a modular, rack-mountable storage array that delivers high performance, high reliability, and flash- accelerated scalability. The storage system contain dual controllers, each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and iSCSI and Fibre Channel I/O modules.
(SFF) disk drives or 12 large form factor (LFF) disk drives. • An associated number of drive trays. The VSP G200 supports 64 GB of high-speed cache memory. The DIMMs are arranged as 32 GB per controller. The VSP G200 interfaces consist of: •...
DB60C Related references • Examples of supported VSP G200 configurations on page 18 Features The features described in the table are included with VSP G200. Feature Value Maximum cache memory supported 64 GB Maximum number of spare drives Maximum number of RAID groups...
All storage systems offer pay-as-you-grow scalability by allowing you to hot- add drives as you need them. Examples of supported VSP G200 configurations The VSP G200 controller chassis provides a built-in compartment for installing drives. The following table lists the maximum number of drive trays and drives supported in a system configuration.
Virtual Storage Platform G200 controllers The Virtual Storage Platform G200 model equipped with dual controllers for communicating with a data host. Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans.
LED might turn off during user maintenance. ALARM LED Off: Normal operation. Red: Processor failure (system might be down). Go to the Customer Contact Us page at Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
(SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. POWER ON/OFF (main switch) Powers the storage system. Small form factor drives The twenty-four 2.5-inch small form factor drives are Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Restoring, or sequential shutdown in progress. CTL WARN LED Amber blink one time: Failure with fan 0. Amber blink two times: Failure with fan 1. Cache flash memory Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Power supply unit CBSS/CBSL AC power supply unit LEDs and connectors The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and connectors. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
CBSL with front panel bezel The following table describes the definitions of the CBSL controller front panel bezel LEDs. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 29
Note: Removing a controller can cause the POWER, READY, WARNING, and ALARM LEDs on the front panel to turn off. These LEDs return to their on state after the storage system recovers from the controller replacement. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
The slots are organized in the following order: 10 11 CBSL rear panel The following table describes the definitions of the CBSL controller rear panel LEDs. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 31
Maintenance LAN port (left) and user LAN port (right). Uninterruptible power supply (UPS) port ALARM LED (for cache flash memory) Red: Cache flash memory can be removed. Backup module Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
LEDs and connectors. Number Item Description Receptacle Connects to the power cable provided with the storage system. AC IN LED Blue: AC input is normal. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
LEDs display the operating status of the storage system. Front end module descriptions The front end module LEDs display the operating status of the module. 10-Gbps iSCSI board LEDs and connectors (optical) Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet LAN cables. 10-Gbps iSCSI board LEDs and connectors (copper) Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Description Fibre Channel connectors Connect to Fibre Channel cables. STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 36
8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel Ports (left to right) CHB number Port 1 Port 2 Port 3 Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Blue: Normal link status at 16- Gbps. Green: Normal link status at 4- Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
The back end module LEDs display the operating status of the module. Number Item Description PATH 1 connector Connects to a drive tray. PORT LED Blue: Normal link status. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
□ Dense intermix drive tray □ SFF and LFF AC power supply unit LEDs and connectors □ SFF and LFF DC power supply unit LEDs and connectors □ Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Can be turned on or turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. SFF front panel without bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Small form factor drives The twenty-four 2.5-inch small form factor drives are positioned vertically. The slots are organized from 0 to 23. SFF rear panel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
AC IN LED Green: Normal operation. ALM LED Red: Power supply unit can be replaced. RDY LED Green: Normal operation. Large form-factor (LFF) drive tray LFF with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Can be turned on or turned off by the maintenance utility. ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked up. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
READY LED Green: Drive tray is operational. LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
If the storage system is turned on, the LED stops blinking when the capacitor is finished charging (approximately two minutes). Note: ACT indicator is only printed on some types of FMDs. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Green: Power supply unit is AC IN LED operating normally. ALM REPLACE LED Red: Power supply unit can be replaced. Dense intermix drive tray Dense intermix drive tray with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Dense intermix drive tray display LEDs Number Item Description Green: Normal operation. Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
PATH (OUT) connector Connect to a drive tray. PATH (IN) LED Blue: IN side port is linked up. PATH (IN) connector Connects to a controller or drive tray. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
SFF and LFF DC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with DC power supply units. The DC power supply units include LEDs to display its operating status. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 54
Number Item Description Green: Normal operation. RDY LED Green: DC input is operating DC IN LED normally. Red: Power supply unit can be ALM LED replaced. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Green: Host port expansion is POWER LED turned on. Amber: PCIe module is turned Off: PCIe module is turned off. Lock or unlock the front bezel. Safety lock PCIe switchboard Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 58
Off: Basic PCIe is normal or not set. Link Option LED Green: Option PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Host port expansion chassis power supply Number Item Description ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
The SVP is available as: • A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7. • A software application that runs Windows 7 Professional x64 Service Pack 1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host, or Linux KVM host.
• Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button.
LAN ports. Number Description Power socket. Attach the power cable supplied with the SVP. Four LAN ports arranged as follows: LAN3 LAN4 LAN1 LAN2 VSP service processor server Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
For more complex maintenance activities, contact customer support. Storing the storage system □ Powering off the storage system □ Removing cables □ Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 67
(1) to release the latch and remove the SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 68
Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
2.5-inch drives, 3.5-inch drives, and flash drives. The chassis consists of an ENC and AC-DC power supplies equipped with built-in cooling fans. Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 71
Maximum number of drives that 24 drives CBSS can be mounted 12 drives CBSL SFF drive tray 24 drives LFF drive tray 12 drives FMD drive tray 12 drives Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 72
Up to 86º F (30º C) 5 years 4 years Up to 93.2º (34º C) 4 years 3 years Up to 104º (40º C) 3 years 2 years Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 73
WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm) SFF drive tray WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 74
When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
3.5-type: 5874.22 GB, 7,200 3.5-type: 9790.36 GB, 7,200 Maximum number of drives that 24 drives CBSSD, SFF drive tray can be mounted 12 drives CBSLD, LFF drive tray Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 77
512 bytes Maximum number of hosts using a Fibre Channel switch Maximum number of hosts using a network switch RAID specifications D: Data drive, P: Parity drive. Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 78
WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) LFF drive tray WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 79
The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled. Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 80
3 hours every six months. Insulation performance Item Specifications Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more Mechanical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Electrical specifications for VSP G200 The electrical specifications are described for the storage system. Electrical specifications □ VSP G200 electrical specifications (DC power supply) □ Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Connector: Positronic Industries Inc., PCS Series Heat value 1800 1550 1120 (kJ/h) Steady-state power (W) Power consumption Input current 15.9 15.9 No connection Remote adapter No connection Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Environmental specifications for VSP G200 The environmental specifications are described for the storage system. Environmental specifications □ VSP G200 environmental specifications (DC power supply) □ Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Transport, storage -22°F to 140°F -22°F to 122°F (-30°C to 50°C) (-30°C to 60°C) Temperature 10 or less change rate (°C/h) Humidity State Percentage Operating 8 to 80 Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 87
900 (Environmental temperature: 10°C to 35°C) when DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed. (Environmental temperature: 10°C to 40°C) 3,000 3,000 (Environmental temperature: 10°C to 32°C) Operating (m) (Environmental temperature: 10°C to 32°C) Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack. Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Non-operating (m/s2) 5.0 or less (5 to 300 Hz): No critical damage for product. 9.8 (1.0 G) Adopt fall- prevention safety measures. Transport (packed) 5.0 or less (m/s2) Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 90
Therefore, this standard value might be exceeded if the maximum load continues under high- temperature environment or if a system failure occurs. Standby 55 dB Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
The following tables describe the standards and specifications for using iSCSI in a hosting environment. iSCSI standards □ iSCSI specifications □ iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Path I/O) Link 10 Gbps SFP+ Transfer speed 10 Gbps Connector type Cable Optical OM3, OM2 MMF cable Network switch L2 or L3 switch Should comply with IEEE802.3ae iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 93
The setting of the corresponding host should also be changed to log in the new port number. • The new port number might conflict with other network communication or be iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 94
Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Replacement parts Part replacement is essential for maintaining the high performance of the system. Replacing system components is covered by the maintenance service contract. Battery unit □ Replacement parts Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery. Replacement parts Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
The storage system supports a variety of data and power cables for specific hosting environments. Fibre Channel cables □ iSCSI cables □ Managing data cables □ AC power cables □ Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
If this default value is set, Fabric is set to ON automatically. Note: To connect to the server by the 16-Gbps direct connection, the Fabric Emulation function of the Hitachi host adapter is required. Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 99
Gbps. If this default value is set, Fabric is set to ON automatically. Note: The five Hitachi FC HBAs also have an alternate option of Fabric Emulation. When the HBA is configured to use this mode, treat it as an attached switch and set the storage port to Fabric = On and Connection Type = P-to-P.
Page 100
One side Other side LC-LC cable Optical Equivalent to 50, 125 μm, LC connector LC connector (shortwave) DXLC-2P-PC- 62.5, 125 μm xxM-GC50, Multimode Wavelength: 125-2SR 850 nm (OMx) Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
• Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows iSCSI cables When constructing an iSCSI system with a direct connection or switch connection, consider the following: Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 102
The following figure shows the type of optical connector that connects the storage system optical iSCSI ports. • LC connector type • Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
1.73 inch (40 mm) Protecting cables Damage to your Fibre Channel and Ethernet cables can affect the performance of your storage system. Observe the following guidelines to protect cables Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended.
CEI 23-50 Argentina 200-240 10, 15 IRAM 2073 Australia 200-240 10, 15 AS-3112 China 200-240 10, 16 GB-1002 New Zealand 200-240 10, 15 AS-3112 Denmark 200-240 DK 2-5 Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
6 AS C112 Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: •...
Cable management Rack installations should be planned for operational efficiency, ease of maintenance, and safety. Hitachi offers the Backend Configuration Utility (BECK), a graphical, cable-management application that can relieve the typical cable congestion created when populating a rack with storage systems and their accessories.
Page 109
Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 110
Data and power cables Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
HBA, the host might not be able to recognize the VOL. If this problem or other problems occur, revert to the default value of EF. * A value set as the default value. Port address mapping Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
Hitachi Universal V2 Rack power distribution units The Hitachi Universal V2 Rack is equipped with specific power distribution units (PDU) for Americas, APAC, and EMEA regions. The PDUs can provide electrical power to the storage system in a single-phase or three-phase configuration.
Americas single-phase PDU 1P30A-8C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 1 Americas PDU for the Hitachi Universal V2 Rack (Single-phase PDU 1P30A-8C13-3C19UL.P) Part Number Region Phase Description 1P30A-8C13-3C19UL.P Americas Single • 208V, 30A (24A rated) 60Hz •...
• 4.5 m (14.76 feet) cable Americas three-phase PDU 3P30A-8C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 3 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-8C13-3C19UL.P) Part Number Region Phase Description 3P30A-8C13-3C19UL.P...
APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P The following figure and table describes the specifications of the PDU. Figure 6 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single- phase 1P32A-9C13-3C19CE.P) Part Number Region Phase Description 1P32A-9C13-3C19CE.P APAC and EMEA Single •...
4.5 m (14.76 feet) cable APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P The following figure and table describes the specifications of the PDU. Figure 8 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three- phase 3P16A-9C13-3C19CE.P) Part Number Region...
EN5524: 2010 EN61000-3.2:2006+A1 EN61000-3.3:2008 Safety certifications UL and CSA cTUVus USA and Canada 60950-1:2007 EN60950-1:2006+A1 Germany IEC60950-1:2005+A1 All CB countries IEC60950-1:2005+A1 S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan Regulatory compliance Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
Page 126
Specification Country regulation logo EN60950-1:2006+A1 Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Table 6 Cryptography Standards and Certifications for VSP G200 Standard Certification Country regulation Description Federal Information #2694 FIPS 140-2 USA and Canada Encryption back end Processing Standards...
Page 132
Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0) 1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com Contact Us www.hds.com/en-us/contact.html...