Siemens NIC-C Installation Instructions Manual

Siemens NIC-C Installation Instructions Manual

Fire alarm network interface card
Hide thumbs Also See for NIC-C:

Advertisement

Installation Instructions
Model NIC-C
Network Interface Card
SIEMENS
RESET
POWER
CARD FAIL
CAN FAIL
HNET FAIL
XNET FAIL
GND FAULT
LOOP A FAIL
LOOP B FAIL
ACTIVE NETWORKS
CAN
HNET
XNET
HNET/XNET STYLE
STYLE 7
STYLE 4
GROUND FAULT
ENABLED
DISABLED
+
1
-
HNET
Figure 1

NIC-C Network Interface Card

Siemens Building Technologies
NIC-C
NETWORK
PORT
+
+
2
3
-
-
Fire Safety

Advertisement

Table of Contents
loading

Summary of Contents for Siemens NIC-C

  • Page 1: Installation Instructions

    HNET FAIL XNET FAIL GND FAULT LOOP A FAIL LOOP B FAIL ACTIVE NETWORKS HNET XNET HNET/XNET STYLE STYLE 7 STYLE 4 GROUND FAULT ENABLED DISABLED NETWORK PORT HNET Figure 1 NIC-C Network Interface Card Siemens Building Technologies Fire Safety...
  • Page 2 Siemens Building Technologies P/N 315-033240-4 Fire Safety...
  • Page 3 S1, Ground Fault Detection Control: It is recommended to enable ground fault detection on ONLY one NIC-C in the system. (One for HNET and if used, one for XNET.) If multiple NIC-Cs have ground fault detection enabled, multiple troubles will be reported to the PMI when a ground fault is present.
  • Page 4 S3, NIC-C Options: RESET SWITCH 96 PIN DIN PLUG CONNECTOR S4, Reset Switch: NETWORK PORT NETWORK ADDRESS Disconnect BATTERY and AC prior to working on equipment. Figure 2 NIC-C Switch Location B– B– A– A– TERMINAL BLOCK ON THE CC-5/CC-2...
  • Page 5 7 . CC-5 terminals 9 - 14 are not connected and can be used DO NOT USE DO NOT USE DO NOT USE to tie shields together. Figure 4 NIC-C Style 4 Network Wiring PAIR B SUPERVISED POWER LIMITED PAIR A NOTES: SUPERVISED POWER LIMITED 1.
  • Page 6 24V RET same enclosure. EOLR P/N 140-099066 (SUPPLIED WITH NIM-1W) COMPANION NIM-1M A PAIR A PAIR B PAIR B PAIR (OMIT FOR STYLE 4) NIC-C Figure 7 Wiring The NIC-C To An XNET Bridge Siemens Building Technologies P/N 315-033240-4 Fire Safety...
  • Page 7 24V 4A FAIL LCM-8 LCM-8 LCM-8 SCM-8 SCM-8 SCM-8 LCM-8 LCM-8 LCM-8 BATTERY SCM-8 SCM-8 SCM-8 FCM-6 N GND LCM-8 LCM-8 LCM-8 SCM-8 SCM-8 SCM-8 Buzzer Figure 8 CAN Wiring - Single Enclosure Siemens Building Technologies P/N 315-033240-4 Fire Safety...
  • Page 8 24V 4A FAIL REFER TO SINGLE ENCLOSURE WIRING DIAGRAM FIG. 6 BATTERY 24 V INCLUDED IN CAN TERMINATOR KIT N GND (SHIPPED WITH THE NIC-C) Figure 9 CAN Wiring - Single Remote Enclosure SHIELD CONNECTION POINTS LCM-8 SCM-8 CAN +...
  • Page 9 FIG. 6 CAN + CAN – SHIELD BATTERY INCLUDED IN CAN TERMINATOR KIT N GND (SHIPPED WITH THE NIC-C) Figure 11 CAN Wiring - Remote Enclosure Without An RNI Figure 12 Installing The NIC-C Siemens Building Technologies P/N 315-033240-4 Fire Safety...
  • Page 10 Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. Siemens Gebäudesicherheit 8 Fernwood Road 2 Kenview Boulevard GmbH & Co. oHG Florham Park, New Jersey 07932 Brampton, Ontario L6T 5E4 CN D-80930 München P/N 315-033240-4...