Security Integrated
In conjunction with STEP 7, each CPU offers password-based know-how protection against
unauthorized reading out or modification of the program blocks.
Copy protection provides reliable protection against unauthorized reproduction of program
blocks. With copy protection, individual blocks on the SIMATIC memory card can be tied to
its serial number so that the block can only be run if the configured memory card is inserted
into the CPU.
In addition, you can assign various access rights to different user groups in the controller
using four different authorization levels.
Improved manipulation protection allows changed or unauthorized transfers of engineering
data to be detected by the controller.
The use of an Ethernet CP (CP 1543-1) provides you with additional access protection
through a firewall or possibilities to establish secure VPN connections.
Safety Integrated
The fail-safe CPUs are intended for users who want to implement demanding standard and
fail-safe applications both centrally and decentrally.
These fail-safe CPUs allow the processing of standard and safety programs on a single
CPU. This allows fail-safe data to be evaluated in the standard user program. The integration
also provides the system advantages and the extensive functionality of SIMATIC for fail-safe
applications.
The fail-safe CPUs are certified for use in safety mode up to:
● Safety class (Safety Integrity Level) SIL 3 according to IEC 61508:2010
● Performance Level (PL) e and Category 4 according to ISO 13849-1:2006 or according to
EN ISO 13849-1:2008
Additional password protection for F-configuration and F-program is set up for IT security.
Design and handling
All CPUs of the SIMATIC S7-1500 product series feature a display with plain text
information. The display provides the user with information on the order numbers, firmware
version, and serial number of all connected modules. In addition, the IP address of the CPU
and other network settings can be adapted locally without a programming device. Errors
messages are immediately shown on the display in plain text, thus helping customers to
reduce downtimes.
Uniform front connectors for all modules and integrated potential bridges for flexible
formation of potential groups simplifies storage. Additional components such as circuit
breakers, relays, etc., can be installed quickly and easily, since a DIN rail is implemented in
the rail of the S7-1500. The CPUs of the SIMATIC S7-1500 product series can be expanded
centrally and in a modular fashion with signal modules. Space-saving expansion enables
flexible adaptation to each application.
The system cabling for digital signal modules enables fast and clear connection to sensors
and actuators from the field (fully modular connection consisting of front connector modules,
connection cables and I/O modules), as well as easy wiring inside the control cabinet
(flexible connection consisting of front connectors with assembled single conductors).