B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 71)
ADDR
REGISTER NAME
600B
87L Current Differential Ground Restraint
600C
87L Current Differential Ground Delay
600D
87L Current Differential Key DTT
600E
87L Current Differential External Key DTT
6010
87L Current Differential Target
B
6011
87L Current Differential Event
6012
87L Current Differential Tap 2 Setting
6013
87L Current Differential Signal Source 2
6014
87L Current Differential Signal Source 3
6015
87L Current Differential Signal Source 4
Continuous Monitor (Read/Write Setting)
6130
Continuous Monitor Function
6131
Continuous Monitor I OP
6133
Continuous Monitor I Supervision
6135
Continuous Monitor V OP
6137
Continuous Monitor V Supervision
6139
Continuous Monitor Target
613A
Continuous Monitor Events
Negative Sequence Time Overcurrent (Read/Write Grouped Setting) (2 modules)
6300
Negative Sequence Time Overcurrent 1 Function
6301
Negative Sequence Time Overcurrent 1 Signal Source
6302
Negative Sequence Time Overcurrent 1 Pickup
6303
Negative Sequence Time Overcurrent 1 Curve
6304
Negative Sequence Time Overcurrent 1 Multiplier
6305
Negative Sequence Time Overcurrent 1 Reset
6306
Negative Sequence Time Overcurrent 1 Block
6308
Negative Sequence Time Overcurrent 1 Target
6309
Negative Sequence Time Overcurrent 1 Events
630A
Reserved (7 items)
6311
...Repeated for Negative Sequence Time Overcurrent 2
Negative Sequence Instantaneous Overcurrent (Read/Write Grouped Setting) (2 modules)
63C0
Negative Sequence Instantaneous OC 1 Function
63C1
Negative Sequence Instantaneous OC 1 Signal Source
63C2
Negative Sequence Instantaneous Overcurrent 1 Pickup
63C3
Negative Sequence Instantaneous Overcurrent 1 Delay
63C4
Negative Sequence Instantaneous OC 1 Reset Delay
63C5
Negative Sequence Instantaneous Overcurrent 1 Block
63C7
Negative Sequence Instantaneous Overcurrent 1 Target
63C8
Negative Sequence Instantaneous Overcurrent 1 Events
63C9
Reserved (8 items)
63D1
...Repeated for Negative Sequence Instantaneous OC 2
Overfrequency (Read/Write Setting) (4 modules)
6470
Overfrequency 1 Function
6471
Overfrequency 1 Block
6473
Overfrequency 1 Source
6474
Overfrequency 1 Pickup
6475
Overfrequency 1 Pickup Delay
6476
Overfrequency 1 Reset Delay
6477
Overfrequency 1 Target
6478
Overfrequency 1 Events
6479
Reserved (4 items)
647D
...Repeated for Overfrequency 2
648A
...Repeated for Overfrequency 3
6497
...Repeated for Overfrequency 4
B-40
RANGE
1 to 50
0 to 5
0 to 1
0 to 4294967295
0 to 2
0 to 1
0.2 to 5
0 to 6
0 to 6
0 to 6
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
0 to 30
0 to 16
0 to 600
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 5
20 to 65
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 1
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
%
1
F001
seconds
0.01
F001
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
0.01
F001
---
1
F211
---
1
F211
---
1
F211
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F300
---
1
F167
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F001
DEFAULT
25
10
1 (Enabled)
0
0 (Self-reset)
0 (Disabled)
100
0 (None)
0 (None)
0 (None)
0 (Disabled)
0
0
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
1000
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0
0 (SRC 1)
6050
500
500
0 (Self-reset)
0 (Disabled)
0