Download Print this page

LG 4300 Instructions page 4

Dual-handed swingbolt or deadbolt electronic lock

Advertisement

LOCKS USING THE KEY FEATURE MUST BE ORDERED THAT WAY FROM THE FACTORY. PLEASE SEE PRICE LIST FOR
PART NUMBERS FOR LOCKS SET-UP FOR e
SET/CHANGE TIME DELAY VALUES (Manager Only, with e KEY or e
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
2 PRESS 9. Unit signals twice.
3 Enter Delay period value, from 00 to 99 minutes. For example five (5) minutes would be entered by pressing the 0 key and then the 5
key.
4 Enter Open period value, from 00 to 19 minutes. For example two (2) minutes would be entered by pressing the 0 key and then the 2
key. Unit will signal twice.
Note: Selecting 0000 minutes deactivates the Time Delay Feature.
5 Confirm all four values. Unit signals twice and feature is active.
NOTE: If Time Delay is active it may only be deactivated or delay value decreased in Open Period.
RECEIVE AUDIT (Manager Only, with e KEY or e
This function requires Serial Interface (P/N 43087) and LGVIEW Software
1 Plug Interface into PC and open LGVIEW software on PC.
2 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
3 Remove key and connect Interface to front of keypad and click safe icon button on the PC software to begin acquisition.
4 PRESS 7. Unit signals once and Audit will be sent.
5 Disconnect Interface Cable from PC and keypad.
DUAL CODE OPERATION (If feature is active.)
1 Must add second user to open lock. (See ADD USER)
• Second User cannot be disabled or removed.
2 If Time Delay is active, one valid code will start Delay period.
• Both codes required to open lock in Open period.
TIME DELAY OVERRIDE (If feature is active.)
• Must add User 9. (See ADD USER)
- User 9 cannot be disabled or deleted. If the User is disabled or deleted, this feature will no longer function.
• Entry of Override code during Delay period will open the lock.
SILENT SIGNAL ALARM (If feature is active AND optional Alarm Box is connected to an alarm system.)
• Enter last digit of code one number higher or one number lower.
Example:Code:
• The lock will open without any indication that the duress signal has been sent.
WRONG TRY PENALTY
• Entry of four (4) consecutive invalid codes starts a 5-minute delay period.
- LED flashes red at ten (10) second intervals.
• At the end of the delay period, two more consecutive invalid codes will restart an additional 5-minute delay period.
During delay period a single keystroke will respond with three signals.
BATTERY LOW WARNING
• Repeated beeping during an opening indicates that the battery is low and needs immediate replacement. LA GARD recommends the
replacement of batteries at least once annually.
• Uses one (1) 9-Volt Alkaline Battery. LA GARD recommends the use of Duracell™ or Eveready™ Alkaline batteries.
• If battery is depleted and will not allow lock to open, follow instructions found on the User Instructions for your keypad. Lock
contains a non-volatile memory, even with batteries removed the lock will retain all programming.
WARNING: The port for the e KEY II is a data port only. Connecting power to this port will damage the system.
CHANGING YOUR BATTERY
1 Open safe door.
2 Remove battery box cover by pulling the
front portion away from the safe door.
3 The connector is easily removed by
unsnapping it from the two terminals on
the top of the battery.
Never Pull on the Battery Leads
4 Connect a new 9-Volt Alkaline battery to
the battery clip.
5 Push the battery and the leads
completely up into the battery
compartment.
6 Replace the cover and test the unit
several times before closing the door
© copyright 2006
KEY or e
KEY II )
1-2-3-4-5-6
Duress: 1-2-3-4-5-5 or 1-2-3-4-5-7
2788 Small Battery
Box or 2789 Small
Battery Alarm Box
12-239v3
KEY II USE .
KEY II )
CHANGING YOUR BATTERY
1 Open safe door.
2 Remove battery box cover by
pulling the front portion away
from the safe door.
3 Remove six "C" cell Alkaline
batteries.
4 Insert six new "C" cell batteries
5 Replace the cover and test the
unit several times before closing
the door
LA GARD INC - A Member of The Kaba Group
4001 Large
Battery Box or
4002 Large
Battery/Alarm Box