10-2-13 O.C(Over Current) error

Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the IPM Shunt resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after power off.
Is the O.C error occurred?
Is the connection of compressor wire is normal?
Is the O.C error occurred again?
Is the condition of indoor/outdoor temperature
10-14
LED3
LED OFF
YES
YES
YES
normal load?
YES
7-SEG DISPLAY
E464
IPM Over Current(O.C) Error
NO
NO
NO
NO
Is the O.C error
occurred again?
DESCRIPTION
IPM Over Current(O.C) Error
Terminate the service
Connect the comp wire normally
Terminate the service
Restart after returning to the normal load
Terminate the service