Motorola AP 7161 Installation Manual page 27

Hide thumbs Also See for AP 7161:
Table of Contents

Advertisement

AP 7161 Access Point Installation Guide
connections and the top holes on the angle adapter bracket section. Do not tighten the screws until all rotation
and tilt adjustments are complete.
To adjust the position of the access point, rotate the access point bracket section (plus or minus 15 degrees)
11.
and tilt the angle adapter bracket section (up to 45 degrees).
Tighten all hex flange screws to 60 inch pounds (lbf-in).
12.
For mounting with band clamps:
Attach the pole mount bracket section at the desired mounting location using band clamps.
1.
With the angle adapter bracket section positioned so that the open connector slots are on the bottom, attach
2.
the angle adapter bracket section to the pole mount bracket section using two 1/2 inch bolts and nuts. Tighten
the nuts to 30 inch pounds (lbf-in).
Position the access point bracket section so that the bottom of the section with the straight (not bevel cut)
3.
sides is oriented toward the bottom side of the AP with the gore vent. Using a torque wrench or a ratchet and a
10mm socket, or an adjustable wrench, attach (but don't tighten) the access point bracket section to the
AP 7161 with the with four M6 hex flange screws.