Installation Guide
2. Position the U-bolt on the pole and place the pole mount bracket section on the U bolt. Adjust the two 1/2
inch inner nuts until the pole mount bracket section is against the pole and the U-bolt can be secured
tightly to the pole at the desired mounting location.
3. Place the angle adapter bracket section on the U-bolt with the open slot connections on the bottom and
align it with the pole mount section. Attach with two 1/2 inch nuts. Tighten all nuts to 300 inch pounds
(lbf-in).