Panasonic KX-TDA50 Pc Programming Manual page 171

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Feature Manual References
None
Flash—Flash Width (TIE)
Specifies the maximum length of a flash signal received from a TIE line that the PBX can recognize as a
hookswitch flash signal.
Default
800 ms
Value Range
8 ´ n (n=3–191) ms
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Caller ID—Caller ID Start Code
Selects the DTMF code used to detect the beginning of a Caller ID series.
Default
*
Value Range
*, #, A–D
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
3.1.1 Caller ID
Caller ID—Caller ID Information End Code
Selects the delimiter used to separate multiple parameters in a Caller ID series.
Document Version 2010-11
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)