Test
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEC 60255-5
a
Siemens-specified severity levels
EMI and Environmental Type Tests
Description
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Voltage Dips & Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on D.C.
Power Supply
Dielectric Strength
H.V. Impulse
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C Power ports
A.C. Power ports
Earth ground ports
Enclosure Ports
D.C. Power ports
A.C. Power ports
30% for 1 period, 60% for 50 periods
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
D.C. Power ports
Signal ports
2 kVAC (Fail-Safe Relay output)
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Test Levels
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
10 V
10 V
10 V
10V
40 A/m, continuous,
1000 A/m for 1 s
1000 A/m for 1 s
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
100% for 5 periods,
100% for 50 periods
2.5 kV common, 1 kV
differential mode@1 MHz
2.5 kV common, 1 kV
differential mode@1 MHz
2.5 kV common, 1 kV
differential mode@1 MHz
30 V Continuous, 300 V for 1s
30V Continuous, 300V for 1s
10%
1.5kVDC
2 kVAC
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Chapter 6
Certification
Severity
Levels
4
3
4
3
3
3
3
a
Note
5
3
3
3
4
4
3