Lens wizard menu
Function
SET BACK FOCUS NOW
SET LVL
EXIT
Adjustment procedure DC-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Adjustment procedure Manual-iris Lens:
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
5. Exit the menu.
Adjustment procedure Video-iris Lens:
1. Unlock the back focus locking button.
2. Access the "Lens Wizard" menu.
3. The "SET BACK FOCUS NOW" option is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Select the "SET LVL" option in the menu, and the LEVEL bar appears.
6. Adjust the level potentiometer located on the lens until the LEVEL bar is in the
central position.
7. Lock the back focus locking button.
8. Exit the menu.
Description
Back focus the lens (see 'Back focus adjustment'). The scene is
focused at maximum lens opening to ensure that the object of
interest remains in focus in bright and low-light conditions.
When a Video-iris lens is detected, a level potentiometer is
displayed to obtain the best picture performance. The lens
wizard includes a level detector meter that must be set to the
center using the potentiometer for best results.