Performance

Control Number

Determines the MIDI Control Change numbers common for the entire system. You can use the Knobs on
the front panel and external controllers by assigning appropriate MIDI Control Change numbers.
NOTE
External controllers include external sequencers and external MIDI controllers.
[PERFORMANCE]  [EDIT]  PART [COMMON]  [Control]  [Control Number]
Operation

Ribbon Ctrl (Ribbon Controller Control Number)

Determines the Control Change Number generated by using the Ribbon Controller.
Even when the instrument receives MIDI message with the same Control Change Number specified here
from the external equipment, the instrument assumes that the message is generated by operating the
Ribbon Controller.
Settings:
Off, 1 – 95

Breath Ctrl (Breath Controller Control Number)

Determines the Control Change Number received from the external equipment such as a Breath Controller.
Even when the instrument receives MIDI message with the same Control Change Number specified here
from the external equipment, the instrument assumes that the message is generated by operating the
Breath Controller.
Settings:
Off, 1 – 95
Foot Ctrl 1/Foot Ctrl 2
(Foot Controller 1 Control Number/Foot Controller 2 Control Number)
Determines the Control Change Number generated by using a Foot Controller connected to the FOOT
CONTROLLER [1] /[2] jack.
Even when the instrument receives MIDI messages with the same Control Change Number specified here
from the external equipment, the instrument assumes that the message is generated by operating the Foot
Controller.
Settings:
Off, 1 – 95, Super Knob
Assign SW 1/Assign SW 2
(Assignable Switch 1 Control Number/Assignable Switch 2 Control Number)
Determines the Control Change Number generated by using the [ASSIGN 1]/[ASSIGN 2] button
(Assignable Switch 1/2).
Even when the instrument receives MIDI messages with the same Control Change Number specified here
from the external equipment, the instrument assumes that the message is generated by operating the
[ASSIGN 1]/[ASSIGN 2] button (Assignable Switch 1/2.)
Settings:
Off, 1 – 95
MONTAGE Reference Manual
Edit
Normal Part (AWM2)
Drum Part
Search
Utility
Normal Part (FM-X)
Live Set
Common/Audio
Common/Audio Edit
Common/Audio
General
Audio In
Mixing
Routing
Ins A
Ins B
EQ
Motion Seq
Common
Lane
Control
Control Assign
Control Number
Effect
Routing
Variation
Reverb
Master FX
Master EQ
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Montage 6Montage 8

Table of Contents