Yamaha AD8HR Service Manual page 32

Ad converter with remote preamp
Hide thumbs Also See for AD8HR:
Table of Contents

Advertisement

AD8HR
TEST PROGRAM
1. TESTING WITH TEST PROGRAM
1-1. Test item chart
Test
Item
Test Name
No
1
SRAM
2
FLASH
3
BATT
4
PLLP2
5
d00
PLL
6
ATSC2
7
DSP7
8
DIT A
9
DIT B
10
DIR
11
d01
PANEL LED
12
d02
PANEL SW
13
d06
COM A/B
14
ENCODER
15
COM A (PC)
16
d10
INITIALIZE
* : Loop-back test jig is necessary.
1-2. Setup
1) Test item
AD8HR
2) PC
DOS/V PC 1 unit (Pentium 2000MHz or higher, Windows Xp, or Windows 2000, RS232C x1)
3) Cables
D-SUB 9-Pin serial cross-cable: 1 piece
BNC-BNC cable: 1 piece
Interconnection Diagram
Connect the PC (Windows machine) to the HA-REMOTE 1 terminal. Select the selector switch to the PC side.
Connect the BNC cable between the IN terminal and the OUT terminal on the WORD CLOCK.
32
Description of Test Item
Test address-data bus lines, and do W/R on SRAM and judge pass/fail.
Flash Memory write check - auto testing.
Measure voltage on backup battery.
Do W/R on PLL register and check.
Check the TLC2932 and DIR2.
Do W/R on ATSC2 register and check.
Do W/R on DSP7 register and check. Connect check ATSC2 to SI0.
Make a 4 line serial check with the AK4101 register.
Make a 4 line serial check with the AK4101 register.
Make a 4 line serial check with the CS8415 register. *An internal PLL check with the PLLP2.
Make a visual check of the LED connections.
Make a manual check of the switch connection.
Make auto test of HA REMOTE terminal 1/2 connection
Make manual test of GAIN/DATA encoder connections. (Accepted if test No. can be changed when the encoder it turned.)
Make a visual check of HA REMOTE terminal 1. (Accepted if the test program can communicate with the terminal software.)
Initialize the memory. (Execute if needed.)
AD8HR
HA REMOTE 1
BNC Cable
IN
OUT
Change these connections only during
WORD
CLOCK
the HA REMOTE 1/2 test setup.
HA REMOTE 2
HA REMOTE 1
HA REMOTE 2
Serial
Cross Cable
COM
PC

Advertisement

Table of Contents
loading

Table of Contents