Samsung CLX-9201 Service Manual page 269

A3 color copier
Hide thumbs Also See for CLX-9201:
Table of Contents

Advertisement

► Error Code
A3–3111
A3–3112
A3–3113
A3–3114
► Error message
Sensor Failure: #A3-3111. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3112. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3113. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3114. Turn off then on. Call for service if the problem persists
► Symptom
The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to a defective harness.
► Troubleshooting method
A3–3111 : Center NC sensor is in short status.
A3–3112 : Center NC sensor is in open status.
A3–3113 : Side NC sensor is in short status.
A3–3114 : Side NC sensor is in open status.
1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics >
Engine Test Routines)
109-0000 : Fuser Temperature A
109-0010 : Fuser Temperature B
2) Remove and disassemble the fuser unit.
(Refer to 3.3.23 Fuser Unit)
3) Measure the resistance value of the thermistor (1404-001453). If the measured value is out of 307KΩ~430KΩ
@25℃, replace the thermistor.
4) Install the fuser unit after replacing the thermistor.
5) If the error persists, replace the fuser unit
6) If the error persists after replacing fuser unit, replace the main board(JC92–02429A).
Copyright© 1995-2013 SAMSUNG. All rights reserved.
(JC91-01063A(220V) / JC91–01064A
4. Troubleshooting
(110V)).