Venting; Electrical Connection - Miele DA 3160 Operating And Installation Instructions

Ventilation system
Table of Contents

Advertisement

Installation

7. Venting

Air extraction mode
^ Complete the venting installation, see
"Air extraction".
Recirculation mode
If the hood cannot be installed for air
extraction the appliance must be
connected for recirculation mode.
For recirculation mode a respective
installation kit is recommended which
can be obtained from Miele.
In addition an active charcoal filter is
needed.
^ The non-return flap is not needed for
the recirculation mode. Pull the
non-return flap off the bracket from
the vent connection.
32
^ Insert the hose from below into the air
outlet grille.
^ Insert the hose from the top though
the opening in the cabinet.
^ Secure the ventilation hose on the
vent connection of the hood using a
hose clip.
The non-return flap is not used in
recirculation mode.
^ Screw the air outlet grille onto the
cabinet top.
Make sure that the slats in the grill
point towards the center of the room
and not towards a wall or the ceiling.
^ Install the Active Charcoal Filter (see
"Cleaning and care").

8. Electrical connection

Refer to the notes in "Electrical
connection" and "Important Safety
Instructions" before connecting to
the mains.
^ Plug in the power cord.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Da 3180Da 3190

Table of Contents