System Alarm Setup; Table 2-20 Description Of Alarm - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm is displayed to a multiline terminal and whether or not the alarm information
is reported to the pre-defined destination.
Input Data
Alarm
Type
Report
No.
1
2
0
PKG Initialize
Error.
2
2
0
PKG Mount-
ing Error
Programming Manual
Program 90 : Maintenance Program
Alarm Number
Item
No.
01
02

Table 2-20 Description of Alarm

Name
Content of Alarm
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.

90-10 : System Alarm Setup

Item
Input Data
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
Report
1 = Report (autodial)
Cause
1. PKG not inserted
firmly.
2. PKG was
removed, but not
reinserted firmly.
3. Old PKG data
still reported due to
no initialization.
1.The package is
half.
2.The package is
out of order.
001~100
Action
Recovery
1. Insert PKG firmly.
Upon
initialization,
2. Insert PKG firmly.
the PKG is
3. Delete slot
recognized.
information in
PRG 90-05 and reinsert
the PKG.
1.Please insert the
When the unit
package firmly.
is
2.Please try again after
reconfirmed,
initializing the system
the error is
data once when LED
recovered.
doesn't blink normally.
3.Exchange of
packages.
Issue 1.0
Alarm
Status
ERR
REC
ERR
REC
2 - 705

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents