Component,
Error Code
System, or Test
All
E00
E01
EEPROM
E02
Inlet thermistor
E03
Outlet thermistor Outlet thermistor short circuit
E04
Inlet thermistor
E05
Outlet thermistor Open circuit
E60
Door switch
E61
Control board
E80
Control board
E81
Control board
NOTE: It's important to note error codes should only be used to help identify those components which
require testing. Never replace a part based solely on an error code. The control can generate a false error
if the right conditions exist. Use the code only as a reference and always check the component before
replacing.

Error Codes

No error
EEPROM failure
Inlet thermistor short circuit
Open circuit
Door switch malfunction
L2 and N incorrectly wired (ac input too high)
Invalid UI model
Invalid power model
– 47 –
Description
Critical
Failure
No
Yes
No
No
No
No
No
Yes
No
No