IntelliFlo VS 3050 and VSF+SVRS Pump Setup

Setting up IntelliFlo VS 3050 and VSF+SVRS

IntelliFlo VS 3050 and VSF+SVRS pump speed can be remotely controlled an IntelliTouch system using a
two-wire 50 foot RS-485 communication cable (P/N 350122 ) provided with the pump. The IntelliFlo VS
3050 and VSF +SVRS pump speed can be adjusted from the IntelliTouch Indoor Control Panel to run at any
speed between 400 RPM to 3450 RPM with preset speeds of 750, 1500, 2350, and 3110 RPM. For more
information refer to the IntelliFlo VS Installation and User's Guide (P/N 357269) and the IntelliFlo and
®
IntelliPro
VSF +SVRS Installation and User's Guide (P/N 351420).

Assigning an IntelliFlo VS 3050 pump address

Before assigning a pump address in the IntelliTouch indoor control panel, first set the address on the pump
itself. If there is only one pump, it is always seen as pump #1 by IntelliTouch. In this case you do not need to
set the pump address. When using multiple IntelliFlo VS 3050 pumps with IntelliTouch you need to assign an
address to each pump. The address can be set to #1, #2, #3, or #4. The address set at the pump must match
the IntelliFlo pump number selected in the IntelliTouch indoor control panel.
Note: IntelliFlo pumps cannot be connected in series with other pumps.
Check valves must be used when a pump is used in parallel with other pumps.
To assign an IntelliFlo VS 3050 pump address:
1. Be sure that the pump is powered on and the green power LED is on.
2. Press the Stop buttons to stop the pump.
3. Press and hold both the Start and Stop buttons until the red LED
will starts flashing, then press one of the four speed buttons (1-4) to
select which address to assign the pump. For example, if you are
assigning the pump as pump #1, then press Speed button number 1.
4. Press and hold both the Start and Stop buttons to save the address.
Repeat the process for the other pumps.
Assigning an IntelliFlo VSF +SVRS pump address
To assign an IntelliFlo VSF +SVRS pump address (1-16):
1. Press the Start/Stop button to stop the pump. Be sure that
the green power LED is on and the pump is stopped.
2. Press the Menu button.
3. Press the Up and Down arrow buttons to scroll through the
menu items. Press the Select button to access the
"SETTINGS" menu.
4. Press the Select button to access the "PUMP ADDRESS"
setting.
5. Press the Select button to change the current pump address
(1-16).
6. To enter the new address number, press the Left and Right
arrows to select which digit to modify, then use the Up and
Down arrows to change the selected digit.
7. Press the Enter button to save the changes. To cancel any
changes, press the Escape button to exit edit mode without
saving.
IntelliFlo VS 3050 Speed buttons (1-4)
NOTE: INTELLIFLO "FREEZE"
PROTECTION - If the IntelliFlo pump
is on due to a freeze condition (not
switch on from a relay circuit), and if a
freeze speed is set in IntelliTouch, this
setting takes priority even if the
previous setting is lower than the
default circuit speed. If no "freeze"
protection is set, the pump will be
forced on at the default circuit speed.
Any programmed or manual operation
that actually switches on a circuit, will
cause the pump to run at that speed if
it is higher.
NOTE: INTELLIFLO IN "SERVICE
MODE" - IntelliFlo pumps will STOP
when IntelliTouch is in 'Service" mode.