Download Print this page

Panasonic KE36NKU Specification

Wall mounted heat pump

Advertisement

Quick Links

Split System Submittal Data
System: KE36NKU Indoor: CS-KE36NKU Outdoor: CU-36NKU
Wall Mounted Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
Compressor
No. Used
R.L. Amps - L.R. (A)
Outdoor Unit
Fan Type
Dia (in.) - No. Speeds
Type Drive
No. Poles (RPM)
No. Motors (W)
F.L. Amps (A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Indoor Unit
Fan Type
Dia (in.)
No. Speeds
No. Poles (RPM (Cool / Heat), High)
No. Motors (W)
CFM (Hi/Med/Low) Cooling
CFM (Hi/Med/Low) Heating
Operating Sound-Hi/Me/Lo/ dB-A
(Cool)
Operating Sound-Hi/Me/Lo/ dB-A
(Heat)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Drain Connection Size (in.)
230/208/1/60
16.5-18.0
45
DC Twin Rotary (Inverter)
1
20.0-31.0
Propeller
19-9/32" Auto (Hi, Me, Lo)
Direct / DC Motor
8-750
1-142
19.6-21.5
Aluminum Fin and Copper Pipe
Slit Plate - Inner Rifled
2-21.2
2 - 18.1
8.05
3/8"
Cross Flow
3-15/16" x 32"
Auto and 3 steps
8-1,370 / 1,450
47
630/530/412
671/559/441
49 / 44 / 39
49 / 44 / 39
0.4
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rifled
2-19.5
4.55
3/8"
1-1/4"
Approval:
Date:
Construction:
Unit#:
Drawing#:
Refrigerant
Lbs. - R410a (outdoor unit)
Refrigerant Control
Refrigerant Tubing Connections
Line Length, Max (ft.)
Line Difference, Max (ft.)
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)
Pre-charge, tubing length at
shipment
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Outdoor Unit (Crated) (in.)
Outdoor Unit (Uncrated) (in.)
Weight (lbs.)
(Indoor) Net
(Indoor) Shipping
(Outdoor) Net
(Outdoor) Shipping
(Indoor) Shipping Volume (cu.ft.)
(Outdoor) Shipping Volume (cu.ft.)
R410A
6.5
Electronic Expansion Valve
Flare
165
50 (outdoor lower), 100 (outdoor
higher)
3/8"
5/8"
100'
12-7/32 x 44-7/8 x 14-31/32
11-3/16 x 41-15/16 x 9-1/16
42-3/8 x 40 x 16-3/8
35-13/16 x 37-1/32 x 13-3/8
32.0
39.7
185.2
207.2
4.59
15.88

Advertisement

loading

Summary of Contents for Panasonic KE36NKU

  • Page 1 Split System Submittal Data System: KE36NKU Indoor: CS-KE36NKU Outdoor: CU-36NKU Wall Mounted Heat Pump Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit#: Submitted by: Drawing#: Reference: General Data Power (V/P/Hz) 230/208/1/60 Circuit Ampacity (A) 16.5-18.0 Fuse Size, Max.(A)
  • Page 2 Temperature Control IC Thermistor Timer 24 Hour, Single Event, ON/OFF TIMER Night Setback Included Unoccupied Mode Included High Power Included One Hour Timer Included Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon...
  • Page 3 2-5/32 7/16 dia.1-3/8, 1-3/32, 7/8, 1/2) (knock-out holes Wiring outlet 2-17/32 dia.1-3/8, 1-3/32, 7/8, 1/2) 2-5/32 3-3/8 2-17/32 (knock-out holes dia.1-3/8, 1-3/32, 7/8, 1/2) Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon...

This manual is also suitable for:

Cs-ke36nkuCu-36nku