Download Print this page

Whirlpool EGY60 Instruction Sheet

Compressor start device kit

Advertisement

Available languages

Available languages

Quick Links

for Compressor Start Device Kit for use on
EGY60, EGY70 & EMU60 Type Compressors Only
1.
Pull the refrigerator away from the wall; make sure to protect
the floor from any damage.
2.
Unplug refrigerator or disconnect power.
3.
On the rear of the refrigerator, remove the screws holding
the rear compartment cover in place. Remove the rear
cover. Set the screws and rear cover aside for reuse later.
(See Figure 1.)
4.
Remove the cover and all of the electrical components
from the compressor; pull them straight off of the compressor.
Disconnect from wire harness.
Note: Some models may have a plastic tie strap around
the PTC relay. Remove and discard the strap.
© Whirlpool Corporation 2006
(All Rights Reserved)
INSTRUCTION SHEET
Top Mount Refrigerators with
Kit Contains:
1 Instruction Sheet
1 PTC Start Relay
2 Overloads
1 Wire Jumper
1 Terminal Cover
1 Electrical Cover
FIGURE 1
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death
or electrical shock.
Tools Needed:
1 ¼" Nut Driver
1 Pocket Standard Screwdriver
5.
Identify the compressor type. See Figure 2.
EXAMPLE OF COMPRESSOR
TYPE NUMBER
FIGURE 2
Instruction Sheet 8201770 5/06

Advertisement

loading

Summary of Contents for Whirlpool EGY60

  • Page 1 INSTRUCTION SHEET for Compressor Start Device Kit for use on Top Mount Refrigerators with EGY60, EGY70 & EMU60 Type Compressors Only WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
  • Page 2 • EMU60 & EGY70 use part 2154760 downward while snapping in place. (See Figure 5.) • EGY60 uses part 2214067 Install the new PTC relay. Make sure the start relay and overload are securely mounted all the way on the compressor terminals.
  • Page 3 FICHE D’INSTRUCTIONS Dispositif de mise en marche de compresseur sur réfrigérateurs superposés seulement pour compresseurs EGY60, EGY70 et EMU60 AVERTISSEMENT Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche.
  • Page 4 Engager d’abord le sommet du couvercle puis pousser le couvercle vers le bas pour l’emboîtement • Modèle EGY60, utiliser la pièce numéro 2214067 (Voir Figure 5). Installer le nouveau relais PTC. Vérifier que le relais de mise en marche et le coupe-circuit sont parfaitement branchés sur les bornes du compresseur (Voir Figure 3).
  • Page 5 HOJA DE INSTRUCCIONES para el Juego de dispositivo de encendido del compresor a ser utilizado en refrigeradores con congelador en la parte superior, con compresores de tipo EGY60, EGY70 y EMU60 solamente ADVERTENCIA El juego contiene: 1 hoja de instrucciones 1 relé...
  • Page 6 Para EMU60 y EGY70, use la pieza 2154760 la tapa. • Para EGY60, use la pieza 2214067 Sujete primero la parte superior de la tapa y luego empuje hacia abajo la tapa a la vez que la encaja a presión en su Instale el nuevo relé...

This manual is also suitable for:

Egy70Emu60