Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instructions
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.1.1.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired
8
or replaced immediately by a qualified electrician.
1.1.4.
This product is fitted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.1.5.
Only allow the minimal amount of pump cable to enter water or wet areas. The electrical cable is
designed for use in water and must not be substituted. If damaged contact a qualified electrician.
1.1.6.
Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.
1.2.
GENERAL SAFETY
WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and
regulations.
For cleaning and other maintenance to a swimming pool:
The pump must not be used when people are in the water.
9
The pump must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
9
The pump is to be supplied by an isolating transformer or supplied through a residual current device having a rated residual operating
9
current not exceeding 30mA.
Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
9
WARNING! Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
9
If the supply cordis damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agents.
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use for pumping liquids under 35°C.
9
CAUTION in order to avoid a hazard due to inaddvertant resetting of the thermal cut-out, this appliance must not be supplied through an
9
external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
If pump is used to pump water from a well, drain or deep receptacle, take adequate precautions to stop persons or animals from
9
falling in.
Use the built-in handle to lower or raise the pump. It may be necessary to attach a suitable rope or pulley to the handle.
9
If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
9
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
The pump is to be located where flooding can not occur.
9
In flood situations, user is responsible for ensuring that appropriate back-up procedures, alarms etc are correctly installed in case of pump
9
failure.
© Jack Sealey Limited
SUBMERSIBLE CLEAN WATER PUMP 230V
WPC100.V3, WPC235A.V3, WPC250A.V2
MODEL NO'S:
Original Language Version
WPC100.V3, WPC235A.V3, WPC250A.V2 Issue:1 25/10/22
Recommended fuse rating
WPD235A 5Amp
WPS225A 13 Amp

Advertisement

loading

Summary of Contents for Sealey WPC100.V3

  • Page 1 WPC100.V3, WPC235A.V3, WPC250A.V2 MODEL NO’S: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 2. INTRODUCTION WPC100.V3: Manufactured from corrosion resistant materials with steel motor case and polypropylene base cover. Max. Output: 100L(22gal)/ min, Max. Head: 6m. Minimum water depth of just 5mm. Designed for clean water although this pump will accept small particles up to 5mm.
  • Page 3 Protect it from exposure to direct sunlight. Keep it in the dark, if possible. DO NOT keep pump in a plastic bag to avoid a build up in humidity. WPC100.V3, WPC235A.V3, WPC250A.V2 Issue:1 25/10/22 Original Language Version © Jack Sealey Limited...
  • Page 4 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for:

Wpc235a.v3Wpc250a.v2