Elmdene 20182423N Instruction Sheet

13.8vdc switch mode power supply, for 8/18ah battery and up to 1.0/1.5a* continuous load current

Advertisement

Quick Links

Elmdene International Ltd
3 Keel Close, Interchange Park,
Portsmouth, Hampshire, PO3 5QD, UK
13.8Vdc Switch Mode Power Supply
20182423N
20182424N
for 18Ah Battery and up to 1.5A* Continuous Load Current
F
EATURES
High efficiency cost effective power supply suitable for use in systems designed to comply with
PD6662:2017 and EN50131-6:2017 Grade 3 and Environmental Class II. Rated to provide continuous
current to load for systems requiring 12h standby from a battery. Three independent output signals
are provided for loss of mains fault (EPS**), battery fault (APS**), and power supply fault (GEN).
Comprehensive self-diagnostics can detect blown output and battery fuses, battery fail, low battery
voltage, battery missing and low output voltage. The PSU incorporates intelligent battery
management comprising active full load battery testing, low battery voltage detection and deep
discharge protection to ensure that the battery is not permanently damaged through excessive
discharge. A brownout filter ensures that short mains voltage dips do not create a false loss of mains
alarm. Two LEDs assist with quick and easy installation by showing presence of mains, correct battery
charging or a fault condition. Comprehensive protection is built-in as standard including mains
transient filtering, electronic output overload protection and fuses on the load and battery outputs.
PD6662:2017 and EN50131-6:2017
Type A Grade 3 Environmental Class II
Compliant
Intelligent active battery monitoring
Low quiescent battery monitoring current
during standby operation
Fault signals for loss of mains, battery fail
and power supply fault
Battery deep discharge protection
Battery overvoltage protection
* See table overleaf to determine continuous standby battery current available for given standby times
**EN50131 Definitions:
Technical Support: +44(0)23 9269 6638 (option 3)
for 8Ah Battery and up to 1.0A* Continuous Load Current
EPS = External Power Source
PAK200546-CHUBB_02DC Feb 2021
Tel: +44(0)23 9269 6638
Fax: +44(0)23 9266 0483
Web:
www.elmdene.co.uk
Protection against reverse battery connection
Electronic overload protection shuts down
output until overload or short circuit is
removed (while on mains power)
LED for comprehensive diagnostics
Mains transient suppression and brown-out
filter
Fully enclosed lid and removal from wall
tamper circuit.
APS = Alternative Power Source
©2021 ELMDENE INTERNATIONAL LTD
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 20182423N and is the answer not in the manual?

Questions and answers

Summary of Contents for Elmdene 20182423N

  • Page 1 * See table overleaf to determine continuous standby battery current available for given standby times **EN50131 Definitions: EPS = External Power Source APS = Alternative Power Source Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...
  • Page 2: Specification

    PECIFICATION Mains Input Rated Voltage / (Operational Voltage) 100-240Vac / (90 – 265Vac) Frequency 50/60Hz Input current 20182423N & 20182424N < 1.0A at full load Fuse T2A 20mm HRC Output 20182423N 20182424N Voltage at full load Mains power 13.2 –14.2Vdc (13.8Vdc nominal) Battery standby 9.8 –...
  • Page 3: Installation And Commissioning

    Min 10cm clearance FUSED SPUR L E N 3A min Fasten cables using cable tie Mains Input cable rated: 3A, 300Vac minimum Fig 1 Mounting of Power Supply Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...
  • Page 4: Standby Battery

    Position the battery as shown in Figures 3 - 7 below, avoiding the cover earth connection spades and the cover retaining screws. Fold up ‘Tabs’ to locate battery and secure with the rubber band supplied. Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...
  • Page 5 Fig 4 20182424N Fig 5 20182423N 13) Apply mains power. Check that Green Mains LED is ON. Check there is no fault indicated by the Red Fault LED, refer to diagnostic table on page 7.
  • Page 6 The fault should be rectified before restoring power to the PSU. If any of the fuses require replacing, ensure the correct fuse rating and type is used. Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...
  • Page 7: Maintenance

    Type A Security Grade 3 Environmental Class II Certification Body: Telefication B.V. Edisonstraat 12A Zevenaar, 6902 PK The Netherlands +31 (0) 316 - 583 180 http://www.telefication.com Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...
  • Page 8 (Cd), lead (Pb), or mercury (Hg). For more information see: www.recyclethis.info The packaging supplied with this product may be recycled. Please dispose of packaging accordingly. Technical Support: +44(0)23 9269 6638 (option 3) PAK200546-CHUBB_02DC Feb 2021 ©2021 ELMDENE INTERNATIONAL LTD...