Meterman 30XR User Manual

Meterman 30XR User Manual

Professional digital multimeter with non-contact voltage tester

Advertisement

Quick Links

30XR
Professional
Digital
Multimeter
with Non-Contact
Voltage Tester
Users Manual
• Mode d'emploi
• Bedienungshandbuch
• Manuale d'Uso
• Manual de uso

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30XR and is the answer not in the manual?

Questions and answers

Summary of Contents for Meterman 30XR

  • Page 1 30XR Professional Digital Multimeter with Non-Contact Voltage Tester Users Manual • Mode d'emploi • Bedienungshandbuch • Manuale d'Uso • Manual de uso...
  • Page 2 30 XR MIN MAX HOLD CONTACT VOLTAGE MADE IN TAIWAN PATENTS PENDING metermantesttools.com 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600 V BATT 1.5V 300 V BATT 9V 200mA FUSED 10A MAX 600V FUSED 600V...
  • Page 3: Table Of Contents

    30XR Digital Multimeter Contents Making Measurements................2 Verify Instrument Operation ............... 2 Correcting an Overload ( ) Indication .......... 2 Measuring DC Voltage........See Figure -1-....2 Measuring AC Voltage ........See Figure -2-....2 Preparing for Current Measurements..........2 Measuring DC Current........See Figure -3-....3 Measuring AC Current ........See Figure -4-....
  • Page 4: Making Measurements

    Symbols Used in this Manual Battery Refer to the manual Double insulated Dangerous Voltage Direct Current Earth Ground Alternating Current Audible tone Complies with EU directives Underwriters Laboratories, Inc Fuse Making Measurements Verify Instrument Operation Before attempting to make a measurement, verify that the instrument is operational and the battery is good.
  • Page 5: Measuring Dc Current

    Measuring DC Current See Figure 1. Set the Range Switch to an appropriate A range. Select the highest range and work down if the current level is unknown. 2. Connect the Test Leads: Red to mA or 10A, Black to COM 3.
  • Page 6: Measuring Ncv (Non-Contact Voltage)

    Additional Features Input Lead Warning The 30XR emits a continuous tone to indicate that the user has placed the unit in a potentially dangerous configuration. Specifically, a test lead is in a current connector and the Range Switch is set to measure some other function. If, in this configuration, the DMM is connected to a voltage source, very high and potentially dangerous current could result.
  • Page 7: Product Maintenance

    During the warranty period any defective test tool can be returned to your Meterman Test Tools distributor for an exchange for the same or like product. Please check the “Where to Buy” section on www.metermantesttools.com for a list of distributors near you.
  • Page 8: Warranty

    (1) year period. Meterman Test Tools shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss.
  • Page 9: Electrical Specifications

    EN61010-1: Cat II - 600V / Cat III - negative polarity indication. 300V; Class 2, Pollution degree II. Overrange: (OL) or (-OL) is displayed. The 30XR is recommended for use with Zero: Automatic. local level power distribution, Low battery indication: The B is...
  • Page 10 RESISTANCE (45 Hz - 500 Hz) AC VOLTS Ranges: 200 Ω, 2k Ω, 20k Ω, 200k Ω, Ranges: 200m, 2 V, 20 V, 200 V, 600 V 2M Ω, 20M Ω Accuracy: All ranges, ± (1.5 % rdg + 4 Accuracy: dgts) 200 Ω...
  • Page 11 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600V BATT 1.5V 300V BATT 9V 200mA FUSED 10A MAX 600V FUSED 600V 30 XR HOLD MIN MAX CONTACT VOLTAGE 200m 200m 200k 200m...
  • Page 12 30 XR 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600V BATT 1.5V 300V BATT 9V 200mA FUSED 10A MAX 600V 600V FUSED 600V 600V 30 XR MIN MAX HOLD CONTACT VOLTAGE...
  • Page 13 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600V BATT 1.5V 300V BATT 9V 200mA FUSED 10A MAX 600V FUSED 600V 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m...
  • Page 14 30 XR 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600V BATT 1.5V 300V BATT 9V 200mA FUSED 10A MAX 600V 600V FUSED 600V 600V 30 XR MIN MAX HOLD 200m 200m...
  • Page 15 BATT 30 XR MIN MAX HOLD CONTACT VOLTAGE 200m 200m 200k 200m 10 A 10 A 200m 1.5V 9V BATT 600V BATT 1.5V 300V BATT 9V 200mA FUSED 10A MAX 600V FUSED 600V...
  • Page 16 30XR...