Mec-O-Matic VSP Series Installation, Operation And Maintenance Manual

Mec-O-Matic VSP Series Installation, Operation And Maintenance Manual

Variable speed peristaltic metering pumps

Advertisement

VSP SERIES
Installation, Operation and
Maintenance Manual
VARIABLE SPEED PERISTALTIC
METERING PUMPS
VSP-12 and VSP-20 Models
READ ALL WARNINGS CAREFULLY BEFORE
INSTALLING PUMP

Advertisement

Table of Contents
loading

Summary of Contents for Mec-O-Matic VSP Series

  • Page 1 VSP SERIES Installation, Operation and Maintenance Manual VARIABLE SPEED PERISTALTIC METERING PUMPS VSP-12 and VSP-20 Models READ ALL WARNINGS CAREFULLY BEFORE INSTALLING PUMP...
  • Page 2 PUMP DATA/SPECIFICATIONS Fill in information from pump data label Series: Serial #: Model #: Nominal output: Maximum pressure: Volts/Hz/Amps/Phase: ® KOPkit Tubing material/size: WARRANTY: The manufacturer warrants its equipment of its manufacture to be free of defects in material or workmanship.
  • Page 3: Table Of Contents

    VSP SERIES TABLE of CONTENTS Safety Instructions ..............................3 Technical specifications............................4 Material of Construction............................4 Installation................................4 Operation ................................5 Maintenance .................................6 SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO USE : Secure chemicals and metering pumps, making them inaccessible to children and pets. *** DO NOT PUMP FLAMMABLE LIQUIDS.
  • Page 4: Technical Specifications

    TECHNICAL SPECIFICATIONS Feed Rate: Refer to name plate. * Model VSP-12: 1.6 to 12-gal/day (6 to 45.4-LPD). Tube size: 38in. -O.D. x .19in. -I.D. Model VSP-20: 2.6 to 20-gal/day (9.8 to 75.7-LPD. Tube size: 44in. -O.D. x .25in. -I.D. ‘*’ Denotes approximate feed rates. Actual output Must be measured at time of application, Dimensions: See Figure 1 on page 2.
  • Page 5: Operation

    5. Suction and Discharge Tubing - Take the 15-ft (4.5m) length of .25in.-diameter tubing included, measure and cut the lengths needed to run from the pump head to the injection fitting, and to the chemical tank (Figure 2). Cut the tubing ends square 6.
  • Page 6: Maintenance

    MAINTENANCE NOTE: NO USER SERVICEABLE COMPONENTS INSIDE ENCLOSURE. SHOULD THE POWER SUPPLY CORD BECOME DAMAGED, IT MUST BE REPLACED BY PULSAFEEDER or ITS REPRESENTATIVES or A SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. : Do not attempt to feed chemicals without consulting your chemical feeder dealer or chemical supplier.
  • Page 7 MAINTENANCE (continued) 8. Replace the back cover on the pump head. Be sure it fits tightly against and flush with the housing (Figure #7). 9. Slide the pump head onto the motor drive shaft and turn it clockwise to lock onto the 2 (two) locking collars. 10.
  • Page 8 Page 8 of 8...